10
4.3
U
LTRASONIC
S
ENSOR
I
NSTALLATION
1.
Assemble the Breakaway Sensor
Mounting Brackets (
B11
) as show in
Figure 6
and
Figure 7
.
Figure 6 – Breakaway Sensor Bracket
Exploded View
Figure 7 – Breakaway Sensor
Mounting Bracket Assembly
To assemble the breakaway sensor
bracket:
a)
Assemble the bolt and nut into the
collar.
b)
Grease the bottom edge of the
collar and the angled tube of the
base.
c)
Place the collar onto the angled tube
of the mounting base.
d)
Install the spring between the collar
and the upper ring of the base.
e)
Insert tube through assembly and
tighten the collar
2.
Mount the sensor bracket onto the
boom.
If possible, mount the sensor
brackets while the booms are in
their folded position to ensure
that they will not interfere with
anything when the boom is
folded for transport.
3.
The sensor mounting brackets can be
installed with the base behind (
Figure
10
) or in front of the tube (
Figure 8
).
Mounting the sensor bracket to
the break-away section of the
boom may cause the boom to
drop suddenly as a break-away
occurs. This will occur on
break-away sections which lift
as they break away.
For optimal boom tip
protection, it is recommended
that the sensor be mounted
within approximately two feet
(60cm) of the boom tip.
Please refer to the UC4+ Spray Height
Control system warranty at the end of
the UC4+ Spray Height Control
Operator’s Manual (M01) for implications.
4.
Mount the NORAC UC4+ ultrasonic
sensor (
E02
) into the sensor brackets.
The sensors should be oriented forward
(ahead) of the boom (
Figure 8
and
Figure 10
).
Summary of Contents for UC4+ Hardi OEM
Page 9: ...6 Figure 3 Hydraulic Components Double Acting Figure 4 Hydraulic Components Single Acting ...
Page 20: ...17 Figure 19 Roll Sensors Mounted on an SPC Eagle Boom Chassis Roll Boom Frame Roll Sensor ...
Page 30: ...27 5 3 ITEM C03 44656D CABLE VALVE VARIABLE RATE DT ...
Page 31: ...28 5 4 ITEM C10 44650 35 POWER GENERIC CABLE PULL TYPE ...
Page 32: ...29 5 5 ITEM C11 44651 03 VALVE EXTENSION GENERIC CABLE ...
Page 33: ...30 5 6 ITEM C12 44658 42 INTERFACE CABLE AMP ML ONLY ...
Page 34: ...31 5 7 ITEM C13 44658 60 BYPASS INTERFACE CABLE AMP ...
Page 35: ...32 5 8 ITEM C16 44658 49 VALVE CABLE ROLL PIGTAIL ...