13
4.4
R
OLL
S
ENSOR
I
NSTALLATION
Mount the roll sensors to the included
roll sensor brackets using the machine
screws and nylon lock nuts, as
illustrated in
Figure 12
.
The roll sensors must be
mounted tightly to the
brackets.
Figure 12 – Mounting the Roll Sensor
to the Roll Sensor Mounting Bracket
When mounting the roll sensors, use the
following guidelines and refer to
Figure 13
.
a)
The smaller the distance between
A
and
B
in
Figure 13
, the better the
performance will be.
b)
Ensure the roll sensors are sitting
relatively level when the sprayer chassis
and boom are level.
c)
Both roll sensors must be mounted with
the circular AMP connector facing
towards the Right-Hand Wing (when
looking from the rear of the sprayer).
Figure 13 – General Roll Sensor Mounting Location on a Trapeze Style Boom
Connectors towards
Right-hand Wing