15
the oil. For pull-type sprayers, ensure any hydraulic flow controls are adjusted for normal field
operation. Changing the hydraulic flow controls after or during the system setup will affect the
UC4.5 performance.
8.1.2
Turn On the UC4.5 Control Panel
If this is the first setup for the panel, the process will begin automatically. If the panel was
previously set up, select "Install?" from the setup menu to initiate the Automatic System
Setup.
8.1.3
Select the Sprayer Type
Use the
buttons to toggle through a list of available sprayer types. The types are
listed in
Section 14
.
When the desired type is shown, confirm the selection with the
button.
To exit the install now before changing any settings press the
button.
The control panel is loading all the settings for the sprayer.
8.1.4
Wiring Test
Use the sprayer's manual controls to move the left boom up.
If the wrong boom moves or if the direction is incorrect, stop the setup. Consult the
UC4.5 Installation Manual to check the hydraulic plumbing and electrical wiring of the
system.
The control panel confirms the wiring is correct. Continue the process with the
remaining booms, as shown.
AN2 ?
Type +/-
Left Up
Select
Dfalting
Press
Left Ok