background image

5

NookBox

Installation Guide

IR Universal Remote Control UPIC-5ZBS

IR Signal Learning and Testing 

In order to use the IR Remote Control to control your home appliance, , the IR Remote Control must first learn in the IR signal sent from the 
appliance’s remote control. Follow instruction below to complete the learning process. Please keep the IR Receiver away from direct lighting 
or sunlight during learning process to avoid interference.

Learning

Step 1. Enter IR Learn Mode

 

1. 

Follow instruction in ZigBee Network Setup section to join IR Remote Control into your ZigBee network. 

 

2.  Make sure all switches on the DIP Switch Block are set to OFF position.

 

3.  Press and hold the IR button for 10 seconds and release when IR LED begins to flash.

 

4.  The IR LED will begin flashing slowly to indicate the IR Remote Control is now entering IR Learn Mode.

Step 2. Select Appliance Type

The IR transmitter can learn up to 5 sets of IR signal for 5 different appliances.
Before starting learning, select the appliance number with Dip Switch Set 1 before proceed to learning the signals. The IR signal learnt in will 
be assigned to selected appliance number.
Select the appliance type according to following Dip Switch Set 1 table. For ease of recognition and operation from Climax ZigBee Control 
Panel, each device type has been given a display name on the Control Panel interface, we suggest you to learn in IR signals according to appli-
ance types displayed.      

 

 

   

 “X” means the location of this switch has no effect on appliance selection.

Example: 

 

a.  To select Air Conditioner, slide Switch 1 to ON, and Switch 2-6 to OFF.

 

b.  To select Television, slide Switch 2 to ON, and Switch 3-6 to OFF, ignore Switch 1 position.

Step 3. Learn IR Data

Each appliance type can learn up to 8 IR signals, selected with Dip Switch Set 2. 

Switch 1

Switch 2 

Switch 3

Switch 4

Switch 5

Switch 6

Appliance Type

ON

OFF

OFF

OFF

OFF

OFF

Type 1 (Air Conditioner)

X

ON

OFF

OFF

OFF

OFF

Type 2 (Television)

X

X

ON

OFF

OFF

OFF

Type 3 (Home Audio)

X

X

X

X

ON

OFF

Type 5 (Others)

Switch 1

Switch 2 

Switch 3

Switch 4

Switch 5

Switch 6

Switch 7

Switch 8

IR Signal

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

1

X

ON

OFF

OFF

OFF

OFF

OFF

OFF

2

X

X

ON

OFF

OFF

OFF

OFF

OFF

3

X

X

X

ON

OFF

OFF

OFF

OFF

4

X

X

X

X

ON

OFF

OFF

OFF

5

X

X

X

X

X

ON

OFF

OFF

6

X

X

X

X

X

X

ON

OFF

7

Summary of Contents for UPIC-5ZBS

Page 1: ...1 NookBox Installation Guide IR Universal Remote Control UPIC 5ZBS Infrared Universal Remote Control UPIC 5ZBS Installation Guide...

Page 2: ...r OTA firmware update capability The IR Remote Control utilizes ZigBee technology for wireless signal transmission ZigBee is a wireless communication protocol that is reliable and has low power consum...

Page 3: ...eives IR signal under learning mode or is transmitting IR signal Flash every half second IR data cleared Off IR Remote Control is storing received IR signal under learning mode IR Remote Control is in...

Page 4: ...ity system in the network automatically Please check the security system control panel or CIE Control and Indicating Equipment to confirm if joining and registration is successful 4 If the IR Remote C...

Page 5: ...ceed to learning the signals The IR signal learnt in will be assigned to selected appliance number Select the appliance type according to following Dip Switch Set 1 table For ease of recognition and o...

Page 6: ...R signal will overwrite the old one 5 After finish learning change dip switch setting to learn another IR Signal the repeat procedure from 2 to 4 We suggest to proceed from IR Signal 1 to 8 by sliding...

Page 7: ...ewing the back cover onto the wall or by installing the rotational bracket first then install the main body on the bracket The IR Eye should be pointed to the home appliance you want to control when t...

Page 8: ...ngle to the PCB board LED Signal Coverage Each LED transmits IR signal in cone coverage in front of the LED The LEDs can be selected to transmit signal for each appliance type by using your Gateway Ex...

Page 9: ...Control UPIC 5ZBS IR Transmission Power Use the jumper switches JP2 and JP3 to adjust the IR signal transmission power Factory default is set to Low transmission power JP1 ON Setting the jumper to JP...

Page 10: ...10 NookBox Installation Guide IR Universal Remote Control UPIC 5ZBS...

Page 11: ...11 NookBox Installation Guide IR Universal Remote Control UPIC 5ZBS...

Page 12: ...t Send IR LED 0x1011 UPIC can control up to 5 types of appliances Type 1 5 with its 6 IR LEDs It can be configured to send IR signal with different LEDs using this attribute The Format should be read...

Page 13: ...Type IMPORTANT NOTE Although it is possible to set multiple LED transmission when sending IR Signal please set NO MORE THAN 2 LEDs to be activated The reason for such limitation is that for each extr...

Page 14: ...14 NookBox Installation Guide IR Universal Remote Control UPIC 5ZBS For more information visit www getnookbox com...

Reviews: