Battery and Low Battery Detection

The IR Remote Control uses two 1.5V Lithium batteries as its power source. It features Low Battery Detection function. When low battery 
voltage is detected, the IR Remote Control will transmit Low Battery signal to the coordinator in ZigBee network.

Supervision

The IR Remote Control will transmit a supervision signal to report its condition regularly according to user setting. The factory default interval 
is 30 minutes. The user can also press the ZigBee Button once to transmit a supervision signal manually.

ZigBee Network Setup

ZigBee Device Guideline

The IR Remote Control is a wireless communication protocol that is reliable and has low power consumption and high transmission efficiency. 
Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network and coordinated for data exchange 
and signal transmission.
Due to the fundamental structure of ZigBee network, ZigBee device will actively seek and join network after powering on. Since performing a 
task in connecting network may consume some power, it is required to follow the instructions to avoid draining battery of a ZigBee device. 
 

- Ensure the ZigBee network router/coordinator is powered on before inserting battery into ZigBee device.

 

- Ensure the ZigBee network router/coordinator is powered on and in range while ZigBee device is in use.

 

-Do not remove a ZigBee device from the ZigBee network router or coordinator without removing the battery from a ZigBee device.

 

Joining the ZigBee Network

As a ZigBee device, the IR Remote Control needs to join a ZigBee network to receive command from ZigBee network coordinator to transmit 
IR signal. Please follow the steps bellow to join the IR Remote Control into the ZigBee network.
 

1. 

Insert batteries to power on the IR Remote Control.

 

2.  Press and hold the ZigBee button for 10 seconds, then release it to join the network. Please make sure the permit-join feature on the  

 

 

router or coordinator of your ZigBee network is enabled.

 

3.  After joining the ZigBee network, the IR Remote Control will be registered in the security system in the network automatically. Please  

 

 

check the security system control panel or CIE (Control and Indicating Equipment) to confirm if joining and registration is successful.

 

4.  If the IR Remote Control successfully joins the ZigBee network, the ZigBee LED will flash twice to indicate.

 

5.  After joining the ZigBee network, if the IR Remote Control loses connection to current ZigBee network, the ZigBee LED indicator will  

 

 

flash every 20 minutes. Please check the ZigBee network condition and the IR Remote Control signal range to correct the situation.

 

Removing Device from ZigBee Network (Factory Reset)

To remove the device from current ZigBee network, the IR Remote Control must be put to Factory Reset to complete device removal. Factory 
Reset function will clear the IR Remote Control of its stored setting information and prompt the device to search for new ZigBee network. 
Before removing device, make sure the device is within current ZigBee network signal range
 

1. 

Delete the IR Remote Control from current control panel / CIE.

 

2.  Press and hold the function button for 10 seconds, then release the button to reset device.

 

3.  Upon reset, the IR Remote Control will clear current ZigBee network setting and transmit signal to ZigBee coordinator to remove    

 

itself from current ZigBee network. It will then actively search for available ZigBee network again and join the network automatically. 

OTA Firmware Upgrade

The device supports OTA firmware upgrade feature via ZigBee network, which can be initiated from the ZigBee network coordinator.
Follow steps below to perform OTA firmware upgrade.

 

1. 

You have to access your ZigBee Coordinator to perform the firmware upgrade on the air.

 

2.  On the configuration webpage, select the device that you wish to upgrade and select the new ZigBee 

 

 

firmware provided. Please refer to ZigBee Coordinator User Manual for detail.

 

3.  Press OK to start upgrading process, please do not perform any other actions, or power down the panel.

 

4.  The length of an upgrade will take approximately 20 to 30 minutes. Please note that the duration may 

 

 

vary based on file size or distance between your accessory and coordinator.

 

5.  Wait for firmware to complete update. When the progress reaches 100%, the Device will reset 

 

 

automatically. You can also refresh the webpage again to ensure if the Device firmware 

is successfully 

 

 

updated with the newest version displayed.

Summary of Contents for UPIC-5ZBS

Page 1: ...1 NookBox Installation Guide IR Universal Remote Control UPIC 5ZBS Infrared Universal Remote Control UPIC 5ZBS Installation Guide...

Page 2: ...r OTA firmware update capability The IR Remote Control utilizes ZigBee technology for wireless signal transmission ZigBee is a wireless communication protocol that is reliable and has low power consum...

Page 3: ...eives IR signal under learning mode or is transmitting IR signal Flash every half second IR data cleared Off IR Remote Control is storing received IR signal under learning mode IR Remote Control is in...

Page 4: ...ity system in the network automatically Please check the security system control panel or CIE Control and Indicating Equipment to confirm if joining and registration is successful 4 If the IR Remote C...

Page 5: ...ceed to learning the signals The IR signal learnt in will be assigned to selected appliance number Select the appliance type according to following Dip Switch Set 1 table For ease of recognition and o...

Page 6: ...R signal will overwrite the old one 5 After finish learning change dip switch setting to learn another IR Signal the repeat procedure from 2 to 4 We suggest to proceed from IR Signal 1 to 8 by sliding...

Page 7: ...ewing the back cover onto the wall or by installing the rotational bracket first then install the main body on the bracket The IR Eye should be pointed to the home appliance you want to control when t...

Page 8: ...ngle to the PCB board LED Signal Coverage Each LED transmits IR signal in cone coverage in front of the LED The LEDs can be selected to transmit signal for each appliance type by using your Gateway Ex...

Page 9: ...Control UPIC 5ZBS IR Transmission Power Use the jumper switches JP2 and JP3 to adjust the IR signal transmission power Factory default is set to Low transmission power JP1 ON Setting the jumper to JP...

Page 10: ...10 NookBox Installation Guide IR Universal Remote Control UPIC 5ZBS...

Page 11: ...11 NookBox Installation Guide IR Universal Remote Control UPIC 5ZBS...

Page 12: ...t Send IR LED 0x1011 UPIC can control up to 5 types of appliances Type 1 5 with its 6 IR LEDs It can be configured to send IR signal with different LEDs using this attribute The Format should be read...

Page 13: ...Type IMPORTANT NOTE Although it is possible to set multiple LED transmission when sending IR Signal please set NO MORE THAN 2 LEDs to be activated The reason for such limitation is that for each extr...

Page 14: ...14 NookBox Installation Guide IR Universal Remote Control UPIC 5ZBS For more information visit www getnookbox com...

Reviews: