Installation Guide
NB Smoke Multi detektor SD-29
Parts Identification
1. LED Indicator / Test Button / Emergency Light
Red LED
•
Quick flash: Alarming.
•
Flashes every 1 second: Smoke Detector under Alarm Silence Mode.
•
Flashes every 2 seconds: Smoke Detector under warmup and calibration process.
•
Flashes every 4 seconds with Orange LED: battery exhausted.
•
Flashes briefly: When Learn Button is pressed to see if the device is functioning normally.
•
Turns ON briefly: Transmitting signal.
Orange LED
•
Flash every second: Device power on/Calibration failed.
•
Flashes every 4 seconds with RED LED: battery exhausted.
•
Flashes every 5 seconds: Detecting smoke failed or device malfunctioning.
•
Flashes every 45 seconds: Low battery condition.
Learn/Test Button
•
Press the button once to:
»
Send a supervision / test signal.
»
Check smoke detection chamber.
»
Silence alarm.
•
Press and hold the button for 10 seconds to enter calibration process.
White LED (Emergency Light)
•
The emergency light will begin to flash slowly to alert uses that the system is alarming. (SD-29-HME only)
•
The LED light will turn in for 60 seconds upon any movement detection.
•
For interconnected Smoke Detectors, their white LEDs can be controlled by the system panel according to set Home Automation Rules.
2. IR Lens (SD-29-HM/SD-29-HME only)
3. Buzzer
4. Battery Compartment Fixing Screw
5. Battery Compartment
6. Hooks
7. Mounting Bracket
8. Mounting Holes
•
The Hooks of the Mounting Bracket can hook into this Mounting Hole.
9. Mounting Sheet