Installation Guide

NB Smoke Multi detektor SD-29

Features

Battery

• 

Three CR123 3V Lithium batteries are used to supply power to the Smoke Detector.

• 

The Smoke Detector has a foolproof mechanism which prohibits cover closure without first installing battery.  
Press down on the tab and insert three new batteries into the compartment.

• 

When the Smoke Detector is low on battery, a low battery signal will be transmitted along with regular signal transmissions.  
The Orange LED will flash with accompanying low-volume beep once every 45 seconds.

• 

The Red and Orange LED will flash once every 4 seconds when the battery is exhausted. 

<NOTE>
When changing the battery, after removing the old battery, press the Test Button twice to fully discharge before inserting new battery. 

Getting Started

Step 1.

  Put Control Panel into learning mode. Refer to Control Panel manual for details.

Step 2.

  Insert three CR123 3V Lithium batteries to power on the Smoke Detector. 

 

Orient the battery according to the battery compartment polarity before insertion.

Step 3.

  The Smoke Detector will emit 2 short beeps and begin warm up for 1 minute. The Red LED will flash every 2 seconds.

Step 4.

   During the 1 minute period, learn in the Smoke Detector.

 
 

For SC model (SD-29-HME-SC)

 

»    Press and hold the Learn/Test button for 3 seconds to transmit a Smoke/Temperature sensor learn code.

 

»    Press the Learn/Test button once to transmit an IR sensor learn code.

 

For non-SC model (SD-29-H/SD-29-HM/SD-29-HME)

 

»    Press the Learn/Test button once to transmit a learn code.

 

If the Control Panel receives the signal, the Smoke Detector will emit a 2-tone beep. 

 

Refer to Control Panel manual to complete learning process.

Step 5.

   When the Smoke Detector completes warm-up, it will emit a beep to indicate it has entered calibration mode. 

 

The calibration mode lasts for 1~9 minutes. The Red LED will continue to flash every two seconds during calibration. 

 

Learning the Smoke Detector is prohibited during this period.

Step 6.

  When calibration is completed, the Smoke Detector will emit 2 short beeps and turn off LED to return to normal mode. 

 

If the Smoke Detector is not learnt into panel previously, press the Learn/Test button now to complete learning. 

Testing the Smoke Detector

By pressing the Test Button on the Smoke Detector, you can test if the Smoke Detector is functioning normally.

• 

If the Smoke Detector functions normally, the Red LED will be on for 2 seconds followed by a 2-tone beep.

• 

If the buzzer sounds 2-tone beeps 3 times, the “

Optical Chamber

” on the Smoke Detector is either dirty or out-of-order. 

Test Mode for IR Function

• 

The Smoke Detector can be put into Test mode by pressing the Test Button. Every time the Test Button is pressed,  
the Smoke Detector will transmit a test signal to the Control Panel for radio range test and enter the test mode for 3 mins.  
It will exit Test Mode automatically after 3 minutes and return to normal mode. In Test mode, the sleep timer is disabled,  
and the LED indicator will flash every time a movement is detected. 

Supervision

• 

The Smoke Detector will transmit a supervision signal to report its condition regularly according to user setting.  
The factory default interval is 30~50 minutes. The user can also press the Test Button once to transmit a supervision signal manually.

Summary of Contents for P119602

Page 1: ...1 NookBox Installation Guide NB Smoke Multi detektor SD 29 NB Smoke Multi detektor SD 29 P119602 E6310096 Installation Guide...

Page 2: ...of detecting movements and reporting temperature to users The Smoke Detector can be interconnected with other Smoke Detectors in the alarm system and will raise alarm when any Smoke Detector in the s...

Page 3: ...smoke failed or device malfunctioning Flashes every 45 seconds Low battery condition Learn Test Button Press the button once to Send a supervision test signal Check smoke detection chamber Silence al...

Page 4: ...trol Panel receives the signal the Smoke Detector will emit a 2 tone beep Refer to Control Panel manual to complete learning process Step 5 When the Smoke Detector completes warm up it will emit a bee...

Page 5: ...If the alarm was triggered by High Heat condition 57 25 C the temperature must drop below 49 C for the Smoke Detector to stop alarming The Smoke Detector will transmit a restore signal if no smoke or...

Page 6: ...concentration continues to rise during Alarm Silence period and exceeds a second alarm threshold the Smoke Detector will start alarming again An alarm activated by exceeding the second alarm threshold...

Page 7: ...in the following locations In a ceiling area with full view of its detection coverage unobstructed by appliances and furniture Near the entrance of a room or house to monitor entry activity Limitation...

Page 8: ...it onto the wall The bracket provides bidirectional flexibility Users can either rotate the bracket clockwise or counterclockwise to lock the hook Step 5 The Smoke Detector has three notches on its b...

Page 9: ...9 NookBox Installation Guide NB Smoke Multi detektor SD 29 For more information visit www getnookbox com...

Reviews: