NB Smoke Multi detektor SD-29

Installation

Installation Guideline

•  It is recommended that the installation site be in the center area of the ceiling.

•  Do not locate the detector in the following locations:
 
 » The Kitchen – Smoke from cooking might cause an unwanted alarm.
 » Near a ventilating fan, florescent lamp or air-conditioning equipment – air drafts from them may affect
 

 

the sensitivity of the detector.

 » Near ceiling beams or over a cabinet – stagnant air in these areas may affect the sensitivity of the
   detector.
 » In the peak of an “

A

” frame type of ceiling.

  

Installation Recommendation

•  It is recommended to install the Smoke Detector in the following locations.

 » In a ceiling area with full view of its detection coverage unobstructed by appliances and furniture.
 » Near the entrance of a room or house to monitor entry activity.

•  Limitations

 » Do not install the Smoke Detector exposed to direct sunlight.
 » Avoid installing the Smoke Detector in areas where devices may cause rapid change of temperature  
 

 

in the detection area, i.e. air conditioner, heaters, etc.

 » Avoid large obstacles in the detection area.
 » Do not pointing directly at sources of heat e.g. Fires or boilers, and not above radiators.
 » Avoid moving objects in the detection area i.e. curtain, wall hanging etc.

•  

Press the Test Button to enter Test Mode. Walk around the protected area noting when the LED lights up and check 
that the detection coverage is adequate.

•  When detection coverage is found to be satisfying, installation is now completed.

Summary of Contents for P119602

Page 1: ...1 NookBox Installation Guide NB Smoke Multi detektor SD 29 NB Smoke Multi detektor SD 29 P119602 E6310096 Installation Guide...

Page 2: ...of detecting movements and reporting temperature to users The Smoke Detector can be interconnected with other Smoke Detectors in the alarm system and will raise alarm when any Smoke Detector in the s...

Page 3: ...smoke failed or device malfunctioning Flashes every 45 seconds Low battery condition Learn Test Button Press the button once to Send a supervision test signal Check smoke detection chamber Silence al...

Page 4: ...trol Panel receives the signal the Smoke Detector will emit a 2 tone beep Refer to Control Panel manual to complete learning process Step 5 When the Smoke Detector completes warm up it will emit a bee...

Page 5: ...If the alarm was triggered by High Heat condition 57 25 C the temperature must drop below 49 C for the Smoke Detector to stop alarming The Smoke Detector will transmit a restore signal if no smoke or...

Page 6: ...concentration continues to rise during Alarm Silence period and exceeds a second alarm threshold the Smoke Detector will start alarming again An alarm activated by exceeding the second alarm threshold...

Page 7: ...in the following locations In a ceiling area with full view of its detection coverage unobstructed by appliances and furniture Near the entrance of a room or house to monitor entry activity Limitation...

Page 8: ...it onto the wall The bracket provides bidirectional flexibility Users can either rotate the bracket clockwise or counterclockwise to lock the hook Step 5 The Smoke Detector has three notches on its b...

Page 9: ...9 NookBox Installation Guide NB Smoke Multi detektor SD 29 For more information visit www getnookbox com...

Reviews: