Mounting the Smoke Detector

Step 1.

   Place the Smoke Detector at desired mounting location and use the Range Test function to make sure the Smoke 

 

  Detector can be received by the Control Panel at mounting location.

Step 2.

   Take out the mounting sheet included in the package. The picture’s size equals the Smoke Detector’s actual size and 

 

  the perforated design allows for easy tear-off after installation.

Step 3. 

  Position the sheet tight against the ceiling and use the four holes as template to drill holes and insert wall plugs if required. 

 

  Ensure the wall plugs are flush with the mounting surface.

Step 4.

   Place the mounting bracket on top of the mounting sheet and screw it onto the wall. 

 

  The bracket provides bidirectional flexibility. Users can either rotate the bracket clockwise or counterclockwise to lock the hook.

Step 5. 

  The Smoke Detector has three notches on its back cover for easy identification.

Step 6. 

  Hold the Smoke Detector with extra care and align the three notches with the hooks on the mounting bracket.

Step 7. 

  Rotate clockwise to lock the hook.

Step 8. 

  Installation is now complete. You can now tear off the mounting sheet.

• 

The Smoke Detector is designed to be mounted on the ceiling. The ideal mounting height for the Smoke Detector  
is 2.7 meters to 3 meters. Mounting above 3 meters can affect detection performace. 

(SD-29-HM/SD-29-HME only)

• 

The Smoke Detector provides detection coverage of a 360° circle with 5 meters in diameter.  
Please refer to below figures for the installation details.

 
 

 

 

•  When mounted on the ceiling, the PIR has better detection performance against horizontal movement.

Summary of Contents for P119602

Page 1: ...1 NookBox Installation Guide NB Smoke Multi detektor SD 29 NB Smoke Multi detektor SD 29 P119602 E6310096 Installation Guide...

Page 2: ...of detecting movements and reporting temperature to users The Smoke Detector can be interconnected with other Smoke Detectors in the alarm system and will raise alarm when any Smoke Detector in the s...

Page 3: ...smoke failed or device malfunctioning Flashes every 45 seconds Low battery condition Learn Test Button Press the button once to Send a supervision test signal Check smoke detection chamber Silence al...

Page 4: ...trol Panel receives the signal the Smoke Detector will emit a 2 tone beep Refer to Control Panel manual to complete learning process Step 5 When the Smoke Detector completes warm up it will emit a bee...

Page 5: ...If the alarm was triggered by High Heat condition 57 25 C the temperature must drop below 49 C for the Smoke Detector to stop alarming The Smoke Detector will transmit a restore signal if no smoke or...

Page 6: ...concentration continues to rise during Alarm Silence period and exceeds a second alarm threshold the Smoke Detector will start alarming again An alarm activated by exceeding the second alarm threshold...

Page 7: ...in the following locations In a ceiling area with full view of its detection coverage unobstructed by appliances and furniture Near the entrance of a room or house to monitor entry activity Limitation...

Page 8: ...it onto the wall The bracket provides bidirectional flexibility Users can either rotate the bracket clockwise or counterclockwise to lock the hook Step 5 The Smoke Detector has three notches on its b...

Page 9: ...9 NookBox Installation Guide NB Smoke Multi detektor SD 29 For more information visit www getnookbox com...

Reviews: