26
Configurations and Options
Feature
Description
Alarm Output
Mode
Use this option to turn the external alarm feature on or off. With this feature
you can connect external alarms to the unit to indicate when vibration
and/or air limits have been exceeded. Choose DISABLED or ENABLED. If
you enable the alarm here, you can then go to the Edit menu for the
monitoring mode to select two (2) limits of your choice as a caution and not
to exceed limit. Once either of these limits is exceeded, the external alarm
will activate.
Auto
Calibration
Use this option to generate a calibration record (stored as an event in
memory noted by
a “P”)
after a specified time:
1.
AFTER EVERY 24 HR
2.
AFTER EVERY 48 HR
3.
AFTER EVERY 72 HR
4.
NO AUTO CAL
–
disable this feature.
Each self-trigger event recorded ALWAYS has a calibration signal recorded