background image

Carriage Light with 

Motion-activated Sensor

Tail Assembly

Coach Light

FeatureS

• Automatically comes on when motion is de-

tected.

• Automatically turns light off.

• Photocell keeps the light off during daylight 

hours.

This package includes:

• Mounting screws and wire connectors

requireMentS

• The Light Control requires 120 volts AC.

• If you want to use Manual Mode, the control 

must be wired through a switch.

• 

Some electrical codes require installation by 

a qualified electrician. Please check the codes 

in your area.

Model 52-4477-8

Before installation, record the model num-

ber listed inside the fixture. attach receipt 

in case of possible warranty issues.
Model number:

Wire 

Path

Junction Box 

Screws

Fixture 

Screw

Horizontal Junction Boxes Only:

Remove ground screw and 2 fixture screws from 

the mounting plate. Flip plate over. Reinsert 

ground screw. Insert the 2 fixture screws in the 

holes near the junction box screws holes. Wire 

path must be located as shown above.

Ground 

Screw

Wire Path

Ground Screw

Mounting 

Plate

Fixture 

Screw

inStaLLatiOn

Decorative Nut

Mounting Screw

Bracket 

Mounting 

Screw

Mounting 

Plate

Junction 

Box

598-1285-00

Note:

 We recommend having an assistant help hold 

the lantern assembly during the wiring process.

For best performance, mount the fixture about 6 

feet (1.8 m) above the ground.

1.  Remove two decorative nuts.

2.  Remove mounting plate.

3.  Tighten mounting screws finger tight.

4.  Attach mounting plate to junction box.

  WarninG:  turn  power  off  at  circuit 

breaker or fuse.

installation and

Operating instructions

Summary of Contents for Carriage Light with Motion-activated Sensor 52-4477-8

Page 1: ...er Wire Path Junction Box Screws Fixture Screw Horizontal Junction Boxes Only Removegroundscrewand2fixturescrewsfrom the mounting plate Flip plate over Reinsert ground screw Insert the 2 fixture screw...

Page 2: ...Dwire unlessyouwanttocontrolotherlightsfrom the motion sensor see Optional Wiring Note All wiring must be run in accordance with the Canadian Electrical Code through conduit or another acceptable mean...

Page 3: ...nd connect to the standard light s black wire Connect all white wires together Total fixture ratings must not exceed 500 Watts 4 1 A Wiring Diagram 2 When wiring to control another motion sensing ligh...

Page 4: ...ghtendecorativenutsremovedinstep 1 of Installation section securely against fixture base Mounting Screw Decorative Nut 3 Install one medium base light bulb 100 Watt maximum 4 If applicable place top c...

Page 5: ...towards it and more sensitive to motion across coverage area Sensor Motion OPERATION Mode On Time Works Day Night Test 5 Seconds x x Auto 1 5 or 10 Minutes x Manual To Dawn x back on 1 Second OFF the...

Page 6: ...9 1 m varies with surrounding temperature Sensing Angle Up to 150 240 adjustable Electrical Load Up to 100 Watt Maximum Incandescent Bulb Type Medium Base Type A 100 Watt Maximum Sensor Capacity Up t...

Page 7: ...desired area Lightscomeonin daylight 1 Light control may be installed in a relatively dark location 2 Light control is in TEST 1 The fixture is operating normally under these condi tions 2 Set contro...

Page 8: ...mations sous garantie Num ro de mod le Mod le 52 4477 8 Bo tes de jonction horizontales seulement Retirer la vis de mise la terre et les 2 vis de l appareildelaplaquedemontage Retournerla plaque Repla...

Page 9: ...Deux lanternes d tecteur de mouvement Noir Blanc Vert ou d nud Noir Blanc Vert ou d nud Branchezlesfilsduluminaireauxfilsdanslabo te de raccordement Torsadez ces fils ensemble puis ajoutez y un conne...

Page 10: ...blage2 C blaged unautreluminaire d tecteurdemouvement Ma tre Satellite d nudez le fil rouge des deux luminaires Branchez le fil rouge du luminaire de com mande ma tre aux fils rouge et noir du lumina...

Page 11: ...e queue d corativeoptionnel installezl croud coratif au bas du luminaire maintenant Ensemble facultatif S il y a lieu installer la queue d corative comme illustr ci dessous 1 Vissez l crou hexagonal a...

Page 12: ...plus sensible aux mou vements traversant la zone de couverture Capteur Mode Temps en circuit En fonction jour nuit Essai 5 secondes x x Auto 1 5 ou 10 min x Manuel au choix amanecer x Le moins sensibl...

Page 13: ...ussidelachaleuretpeuvententra ner le d clenchement du capteur Piscine Appareil de climatisation vent de s cheuse Animaux vent de ventilation Circulation automobile Si vous croyez qu une source de chal...

Page 14: ...1 La commande peut tre install e dans un endroit relativement sombre 2 La commande d clairage est en mode essai 1 Le luminaire fonctionne normalement dans de telles conditions 2 R glez le commutateur...

Page 15: ...________________________________ ____________________________________ ____________________________________ ____________________________________ ____________________________________ ___________________...

Page 16: ...________________________________ ____________________________________ ____________________________________ ____________________________________ ____________________________________ ___________________...

Reviews: