background image

4

598-1285-00

teSt 1 5 10 MIN

ON-TIME

LO - M - Hi

SENSITIVITY

Junction Box

Optional assembly

If so equipped, you may install the decorative tail 

as shown below.

1.  Screw hex nut onto bottom of fixture.

2.  Screw extension bar into hex nut.

3.  Slide tail piece and top trim piece onto exten-

sion bar.

4.  Slide bottom trim piece (with drain hole) onto 

extension bar.

5.  Install the decorative nut onto extension bar.

Hex Nut

FinaL aSSeMBLy

1.  Push the wires into the junction box. Make 

sure the wires from the fixture go through the 

wire path, and no wires get pinched.

2.  Slide the fixture assembly onto the mounting 

screws. Tighten decorative nuts removed in step 

1 of 

Installation 

section securely against fixture 

base.

Mounting Screw

Decorative Nut

3.  Install one medium base light bulb (100 Watt 

maximum).

4.  If applicable, place top cover onto fixture and 

attach using the two decorative nuts (included). 

Hand tighten only.

5.  After completing the tests on page 4, caulk 

around  fixture  base  with  silicone  weather 

sealant.

6.  If you will not be installing the optional tail 

assembly, install the decorative nut onto the 

bottom of the fixture now.

Tail Piece

Trim (top)

Trim (bottom with 

hole)

Decorative Nut

teStinG anD aDJuStMentS

1. 

Turn  on  the  circuit  breaker  and  light 

switch.

Note:

 Sensor has a 1 

1

/

2

 minute warm up period 

before it will detect motion. When first turned 

on wait 1 

1

/

2

 minutes.

2.  Set:

  ON-TIME switch to TEST

  SENSITIVITY  dial to Midway

Summary of Contents for Carriage Light with Motion-activated Sensor 52-4477-8

Page 1: ...er Wire Path Junction Box Screws Fixture Screw Horizontal Junction Boxes Only Removegroundscrewand2fixturescrewsfrom the mounting plate Flip plate over Reinsert ground screw Insert the 2 fixture screw...

Page 2: ...Dwire unlessyouwanttocontrolotherlightsfrom the motion sensor see Optional Wiring Note All wiring must be run in accordance with the Canadian Electrical Code through conduit or another acceptable mean...

Page 3: ...nd connect to the standard light s black wire Connect all white wires together Total fixture ratings must not exceed 500 Watts 4 1 A Wiring Diagram 2 When wiring to control another motion sensing ligh...

Page 4: ...ghtendecorativenutsremovedinstep 1 of Installation section securely against fixture base Mounting Screw Decorative Nut 3 Install one medium base light bulb 100 Watt maximum 4 If applicable place top c...

Page 5: ...towards it and more sensitive to motion across coverage area Sensor Motion OPERATION Mode On Time Works Day Night Test 5 Seconds x x Auto 1 5 or 10 Minutes x Manual To Dawn x back on 1 Second OFF the...

Page 6: ...9 1 m varies with surrounding temperature Sensing Angle Up to 150 240 adjustable Electrical Load Up to 100 Watt Maximum Incandescent Bulb Type Medium Base Type A 100 Watt Maximum Sensor Capacity Up t...

Page 7: ...desired area Lightscomeonin daylight 1 Light control may be installed in a relatively dark location 2 Light control is in TEST 1 The fixture is operating normally under these condi tions 2 Set contro...

Page 8: ...mations sous garantie Num ro de mod le Mod le 52 4477 8 Bo tes de jonction horizontales seulement Retirer la vis de mise la terre et les 2 vis de l appareildelaplaquedemontage Retournerla plaque Repla...

Page 9: ...Deux lanternes d tecteur de mouvement Noir Blanc Vert ou d nud Noir Blanc Vert ou d nud Branchezlesfilsduluminaireauxfilsdanslabo te de raccordement Torsadez ces fils ensemble puis ajoutez y un conne...

Page 10: ...blage2 C blaged unautreluminaire d tecteurdemouvement Ma tre Satellite d nudez le fil rouge des deux luminaires Branchez le fil rouge du luminaire de com mande ma tre aux fils rouge et noir du lumina...

Page 11: ...e queue d corativeoptionnel installezl croud coratif au bas du luminaire maintenant Ensemble facultatif S il y a lieu installer la queue d corative comme illustr ci dessous 1 Vissez l crou hexagonal a...

Page 12: ...plus sensible aux mou vements traversant la zone de couverture Capteur Mode Temps en circuit En fonction jour nuit Essai 5 secondes x x Auto 1 5 ou 10 min x Manuel au choix amanecer x Le moins sensibl...

Page 13: ...ussidelachaleuretpeuvententra ner le d clenchement du capteur Piscine Appareil de climatisation vent de s cheuse Animaux vent de ventilation Circulation automobile Si vous croyez qu une source de chal...

Page 14: ...1 La commande peut tre install e dans un endroit relativement sombre 2 La commande d clairage est en mode essai 1 Le luminaire fonctionne normalement dans de telles conditions 2 R glez le commutateur...

Page 15: ...________________________________ ____________________________________ ____________________________________ ____________________________________ ____________________________________ ___________________...

Page 16: ...________________________________ ____________________________________ ____________________________________ ____________________________________ ____________________________________ ___________________...

Reviews: