Company Confidential
the generator as instructed in the window. Take care for external cable and test
jig attenuation losses.
7 Switch off the external RF signal as instructed in the next pop-up window.
8 Press OK and read the SNR result.
The values should be:
GSM850
> 20dB
GSM1900 >
18dB
Measuring front-end power levels using spectrum analyzer
Spectrum Analyzer (SA) level values depend on the probe type and should be validated
using a good sample. The levels that are given here are measured using an hp 85024A
probe.
1 Start Phoenix Service Software and open FBUS connection:
Select
Scan Product
Ctrl-R
Wait until phone information is shown in the lower right corner of the screen.
2 Set operating mode to local mode:
Select
Maintenance
Alt-M
Testing
T
RF Controls
F
Wait until the RF Controls window pops up
3 In the RF Controls window: