Nokia Customer Care
7 - RF Description and Troubleshooting
Company Confidential
RH-47
Issue 1 05/04
Copyright
©
2004 Nokia Corporation
Page 31
Company Confidential
GSM1900 (PCS) transmitter
General instructions for GSM1900 TX troubleshooting
Start the investigations as described in chapter General instructions for TX troubleshoot-
ing “General instructions for TX troubleshooting”.
1 Set operating mode to local mode:
Select
Maintenance Testing
RF Controls
Wait until the RF Controls window pops up.
2 In the RF Controls window:
Select
Band
GSM 1900
Active unit
TX
Operation mode
Burst
RX/TX Channel
661
TX Power Level
5
TX Data Type
Random
The setup should now look like this:
Now the measurement equipment should detect the following output signal of the
phone:
P
out
= +20
±
1dBm @ 1880MHz