Synthesizer
One PLL synthesizer is generating all the required frequencies of both bands for Rx and
Tx. The VCO frequency is divided by 2 or by 4 in Mjoelner depending on the active band.
General instructions for synthesizer troubleshooting
Connect the phone to a PC with DAU-9S cable (RS232). The PC must have Phoenix Ser-
vice Software installed and a PKD-1CS dongle is required.
Follow the instructions in the chapters below.
Checking synthesizer operation
1 Start Phoenix Service Software and open FBUS connection:
Select
Scan Product
Ctrl-R
Wait until phone information is shown in the lower right corner of the screen.
2 Set operating mode to local mode.
3 Start RF Control window:
Select
Maintenance
Alt-M
Tuning
T
RF Controls
F
Wait until the RF Controls window pops up.
4 Set the synthesizer to the following mode:
Select
Band
PCS1900
Active unit
RX
Operation mode
Continuous
RX/TX Channel
661