Infrared does not work
Figure 13:
Fault tree, infra red
Infra Red not working
Measure Vflash1 from IR
module VCC(pin6), should
be 2.78V
Change
UEM(D200)
Check R350, R351, C351
and V350
Replace faulty
component(s)
Use
ST_IR_LOOP_TEST(in
BB Self Tests) in Phoenix
FAIL
OK
FAIL
OK
Use
ST_IR_IF_TEST(in
BB Self Tests) in
Phoenix
OK
Phone OK
Measure Tx Data from
IR module(pin3)
2.78V
, 9.6/115.2kbps
FAIL
Measure Rx Data from
IR module(pin4)
OK
Change IR module
OK
Change UEM
FAIL
OK
UPP or UEM is faulty
FAIL