CCS Technical Documentation
Troubleshooting
RH-13
Issue 1 11/02
ã
Nokia Corporation
Page 37
Step 1. General checking
Figure 19: General checking.
The fastest way to get overview of RX status is to measure RSSI (Received Signal
Strength Indicator) level. This can be done by using signal generator and Phoenix. Note
that this is useful only if the phone has been calibrated when it was OK and the mal-
function have occured after tunings.
1 Set signal generator frequency to 881.46771 MHz and level to -80 dBm.
2 Select RSSI measurement UI in Phoenix (Maintenance => GSM RSSI Meas).
3 Set Band to GSM850 and Rx/Tx channel to 189
Check signal level
at RX band filter
Z801 input
Check V R 4 supply
and components if
these ok => replace
Safari N801
Not OK
OK
Check signal level
at mix1_A input
Replace RX band
filter Z801
Not OK
OK
Check signal level
at IF filter Z804
input (133.2 MHz)
Not OK
OK
Check signal level
at IF filter Z804
output (133.2
MHz)
Not OK
OK
Replace IF filter
Z804
Check signal level
at RX I/Q J808,
J809, J818, J819
Not OK
OK
Start synthesizer
troubleshooting
Replace Safari
N801
OK
Check UEM and
start baseband
troubleshooting
Start synthesizer
troubleshooting
OK
Not OK
Check components
L815,
L814 etc.
Replace Safari N801
OK
Measure VR4 from L815