6
Configure the following parameters:
At least one field must be selected to create a classifier. A maximum of four fields may be
selected to create a classifier; this includes the interface field.
Table 8-21
US Classifier parameters
Field
Description
Interface
Select an interface from the list; for example, None, LAN, 2.4G SSID, or 5G SSID.
The option
None
indicates that all interfaces are selected.
Source MAC
Click to enter a source MAC address.
Destination MAC
Click to enter a destination MAC address.
Source IP
Click to enter a source IP address.
Destination IP
Click to enter a destination IP address.
Source Port
Click to enter a source port.
Destination Port
Click to enter a destination port.
Protocol
Click to enter a protocol.
Priority
Select a priority level from 1 to 8. The lower the number, the higher the priority. No more
than 1 classifier can be created with the same priority.
Figure 8-26
US Classifier page
Configure a XS-2426G-A indoor ONT
Network configuration
Configuring Upstream (US) Classifier