2
Configure the following parameters:
Table 8-20
US Classifier Policy parameters
Field
Description
Tunnel Type
The tunnel type is set to GRE and cannot be modified.
Tunnel Interface
Select a tunnel interface from the list: No Tunnel, GRE Tunnel, or LAN traffic.
VLAN ID
Enter a VLAN ID (0-4094).
VLAN Tag
This field is not configurable. The VLAN tag is set to 8100 (hexadecimal).
Determines the VLAN tag used inside the GRE tunnel.
VLAN Priority
Enter a VLAN priority level (0 to 7). A lower number indicates a higher priority.
IP TOS/DSCP
This field is not configurable. All tunnel packets are generated with a default DSCP value
(usually 0).
Drop
Select this checkbox to drop the packets.
3
Click
Save
.
You can click
Reset
to reset the configured values.
4
To delete a policy, click
Delete
for the applicable policy in the policy table.
A policy can only be deleted if it is not associated with any classifier rules.
You can click
Refresh
to update the displayed information.
5
Click
Network→US Classifier
from the left pane in the 10G PON Home Gateway page, and
select the
Classifier
tab.
All classifiers are displayed in the classifier table in the page.
Configure a XS-2426G-A indoor ONT
Network configuration
Configuring Upstream (US) Classifier
Nokia ONT
Draft
Draft
Nokia – Proprietary and Confidential
Use pursuant to applicable agreements
3FE-49348-AAAA-TCZZA
December 2020
118