![Nokia 7705 Installation Manual Download Page 57](http://html.mh-extra.com/html/nokia/7705/7705_installation-manual_255467057.webp)
SAR-Hm and SAR-Hmc Chassis Installation Guide
Mandatory Regulations
3HE 17810 AAAA TQZZA
© 2022 Nokia. Nokia Confidential Information
Use subject to agreed restrictions on disclosure and use.
57
2.15 Hazardous Locations
2.15.1 Chassis Labels
The 7705 SAR-Hm and 7705 SAR-Hmc chassis display the following labels:
2.15.2 Conditions of Use
• The equipment shall be installed in an enclosure that provides a degree of
protection not less than IP 54 in accordance with EN 60079-0 and EN 60079-7.
Any field wiring connections or cable entries used for this outer enclosure shall
also be suitably certified against the enclosure requirements of EN 60079-0 and
EN 60079-7. The installer shall ensure that the maximum ambient temperature
of the module when installed is not exceeded.
• The equipment shall only be used in an area of at least pollution degree 2, as
defined in IEC 60664-1.
• The chassis shall be grounded as described in the in this manual before use.
• The SIM card shall be connected or disconnected only in a non-hazardous area
or when the device is not energized.
• The end-use enclosure shall provide a Warning label “Do not open while
energized”.
Note:
See
7705 Outdoor Enclosure Requirements for Hazardous Locations
locations requirements pertaining to the 7705 Outdoor Enclosure.