System Works on Infrared Detection principle.
• The system is normally on standby position.
• When a user comes in front of the urinal the 
system starts to count (red led) and waits for 
detection during 5 secs to be sure of the usage. If 
in this duration the user leaves the system switches 
to standby position again. If the user continues to 
use the urinal then the system accepts the usage 

(blue led). After this filter period whenever the user 

leaves, the system waits for 5 secs to be sure that 

the user has already left and then flushes the water. 

The flushed water can be adjusted by the flushing time adjustment switch on the backside of the 

electronic module. There is another switch on the backside of the module for the adjustment of 
detection range.

• Connection water supply: 1” G.
• Detection range: Min 30cm / Max 110 cm (pre-set: 70cm)
• Flush time: 4-10 secs (pre-set: 5 seg)
• Voltage: 24V(230VAC/24VDC adapter included)
Remark: It must be used an independent water supply line / pump for this system. The minimum 
dynamic pressure required for a correct functioning is 3bar, and maximum 8 bar

• Led indications:
Standby: no indication.

After first 5 secs. (filter time for usage), the blue led appears next to red led light

(Optional Manual flush: Big flush activated by showing hand within 10cm in front of the IR sensor, 

to clean the bowl)

Reduced flush volume: The user leaves the sensor range in less than 60 secs (4 secs flush)

Total flush volume: The user leaves the sensor range after 60 secs (8 secs. Flush)

Led indications: Red light indicates that the system is in use. Blue light indicates that the system 
has accepted the use.

Detecta al usuario. Sistema entra en uso.
Detection of the user. The system is on use.
Detection de l’utilizateur. Sisteme en use.
Detecta usuário. Sistema entra em uso.

Sistema descarga 3 litros (aprox.)
Mechanism flushes 3 liters (approx.)
Sisteme chasse 3 litres (approx.)
Sistema descarga 3 litros (aprox.)

Sistema descarga 6 litros (aprox.)
Mechanism flushes 6 liters (approx.)
Sisteme chasse 6 litres (approx.)
Sistema descarga 6 litros (aprox.)

< 75 s.

> 75 s.

> 5 s.

distancia/distance

distancia/distance

distancia/distanc

e

Intervalo de detecção

Tempo de descarga

Z

M

Summary of Contents for Smart Line

Page 1: ...Carretera CV 20 km 2 12540 Vila real Castell n Spain Tel 34 964 50 64 50 Fax 34 964 50 67 93 e mail noken noken com www noken com 100104527_N399999869 Smart Line Elementos empotrados...

Page 2: ...heck the operation of the valves Periodic cleaning and maintenance should be used to avoid the build up of damaging lime scale deposits Bathroom harsh cleaning agent residuals may damage components ma...

Page 3: ...digo code code 1 100128628_N499817004 2 100115133_499816978 3 100113663_N499816984 4 100153749_N499817060 5 100153772_N499817061 6 100115134_N499816976 7 100153773_N499817059 8 100153780_N499817058 9...

Page 4: ...4...

Page 5: ...descarga ADVERTENCIAS No usar materiales abrasivos o cidos para su limpieza Limpiar con trapo h medo No rociar el panel con agua a presi n vapor No instalar el sistema frente a un espejo o a otro sist...

Page 6: ...si n din mica m nima debe ser de 3 bar y la m xima 8 bar Funcionamiento Indicaciones del led Standby sin indicaci n Despu s de los primeros 5 segundos tiempo de ltro para asegurarse de que va a ser us...

Page 7: ...ump for this system The minimum dynamic pressure required for a correct functioning is 3bar and maximum 8 bar Led indications Standby no indication After rst 5 secs lter time for usage the blue led ap...

Page 8: ...dynamique minimale doit tre de 3 bar et la maximale 8 bar Fonctionnement Indications de la led Standby sans indication Apr s 5 secondes temps de ltre pour s assurer qu il va tre utilis la led bleu s...

Page 9: ...press o din mica m nima deve ser de 3bar e a m xima de 8 bar Funcionamento indica es do led Standby sem indica o Ap s os primeiros 5 segundos tempo de ltro para garantir que vai ser usado acende se o...

Page 10: ...r dimension Leaving the pipes longer may cause leakage problems Appropriate anchor and screw must be used for brick or concrete wall or light Pr caution pour l installation Consulter le manuel d instr...

Page 11: ...11 2 1 5 Min 110 Max 140 4 3 6...

Page 12: ...tervalo de detec o Verificar las conexi nes Check the connections V rifier les connections Verificar as liga es Verificar el m dulo electr nico Check the electronic module V rifier le module lectroniq...

Reviews: