Hi5 VR Glove
Developer Guidelines
NOITOM corporation
Dec.2017 V1.2
Hi5 VR Glove Developer Guidelines
3
2.2 Interaction Interfaces
There is one button and one indicator light for each Glove and each Dongle. The
interaction lookup table is as follows:
Button Functions:
Function
Operation and Indication
On Glove/Dongle
Turning on the Glove
Press the button when the Glove is
powered off (click)
Glove
Turning off the Glove
Press and hold the button for 5
seconds (release after the indicator
light turns off)
Glove
Entering pairing mode
Press and hold the buttons for 3
seconds (release when the indicator
lights turn on to a solid state)
Glove & Dongle
Manually switching working
frequency
Short press the button (click)
Dongle
Triggering button event
Short press the button (click)
Glove
( Table 2.2-1 )
Indicator Light States:
Meaning
Indicator Light State
On Glove/Dongle
Powered off
Turned off
Glove
Standby
Breathing
Glove & Dongle
Pairing mode
1Hz flashing (slowly flashing)
Glove & Dongle
Working mode
20Hz flashing (rapid flashing)
Glove & Dongle
The current ambient
environment has magnetic
interference
Solid state turned on (in working
mode)
Glove
Error 01
(Self-test error)
Solid state turned on (right after
power on)
Glove & Dongle
Error 02
(enter Boot mode)
3s off, 0.1s on
Glove & Dongle
( Table 2.2-2 )
Notice
:
The indicator light on the Gloves will turn RED when the battery power is low.