43
REPLACING THE THERMAL PROTECTION
When the temperature of the motor is more than
130
O
C, the module will give a signal to the
controller, then driving speed will automatically
change to low-speed mode. After the temperature
reduces to 110
O
C, the unit will change back to
nomal speed.
If one line of the cable open circuit, the driving
speed will remain slow.
Remove the screw and the plug, then you can
remove the module and replace it.
REPLACING THE LOCK (KEY SWITCH) LKS-101A
Remove
four screws
that fix the plate into vehcle frame
Lift the mounting plate.
Remove the nut of the key switch.
remove the cable of the key switch.
Then you can remove the key switch and replace it.