If channels are to be used to their full capacity use 1mm

2

wire. 

FUSING

If connecting multiple loads to each output, reliability will be improved

if each load is fitted with its own fuse, of an appropriate rating. In

the case of a lamp failure, the lamp fuse will then blow, not the fuse

in the power pack. The other loads on the same channel will then

continue to operate. This greatly reduces the chance of a triac

failure.

The following loads may be connected to the DP10000 

• 230 V filament lamps 

• 230 V halogen lamps 

• Low voltage halogen lighting via standard transformers 

• Low voltage halogen lighting via "Electronic" Transformers. Low

voltage halogen lighting powered by so-called "Electronic

Transformers" may be connected to the DP10000 provided that the

transformers are suitable for Leading-edge-modulated dimmers.

Flickering or failing to dim is a sign that the transformer is not of a

suitable type. NJD recommends using standard laminated or

toroidal transformers for low voltage halogen lighting. 

• LED lighting if suitable for use with a triac dimmer.

• Universal motors The DP10000 will act as a speed control.

The following are NOT suitable for connection to the DP10000 

• Low energy fluorescent lighting (with built-in electronic ballast) 

• Standard fluorescent lighting 

• Synchronous motors 

• Induction motors 

• Lighting effects (such as NJD Chaos, Sword, Predator, Datamoon

etc.) 

• Strobe lighting 

 Discharge lighting

• LED lighting unless specifically designed for use with triac

dimmers.

 The DP10000 is fully suppressed against interference to European

Standards, but problems may be encountered if running the output

Page 5

Summary of Contents for NJ250 DP10000

Page 1: ...NJ250 DP10000 4 10 A ANALOGUE DIMMING PACK Individual 4 channel dimming 2 3 kW power handling per channel Terminal block input and output connectors 0 10 V control inputs Remote enable disable Page 1...

Page 2: ...sted periodically by a qualified electrician at least once every 10 years or at every change of occupancy For office and retail premises and buildings such as village halls the wiring must be inspecte...

Page 3: ...r a 13 A supply the maximum total load is 2990 W which can be made up of either 745 W watts on each of the four channels or different loads on each channel so that the total does not exceed 2990 W but...

Page 4: ...0 W load may be connected to all four channels provided that the unit is operated so that all four channels are not switched on together at full power For high inrush loads Halogen lamps motors transf...

Page 5: ...y be connected to the DP10000 provided that the transformers are suitable for Leading edge modulated dimmers Flickering or failing to dim is a sign that the transformer is not of a suitable type NJD r...

Page 6: ...s from all four channels should be commoned only at the terminal block inside the DP10000 ANALOGUE INPUTS Connect the outputs from any light controller with 0 to 10 V analogue outputs to the 6 way ter...

Page 7: ...y a switch touch panel to the enable input of the DP10000 Connect the common 0 V output from the enabling controller to the 0V terminal A switch may be used if there is no controller available take th...

Page 8: ...e fuse fails check that the output is not being overloaded no more than 2300 W is connected to each output before replacing the fuse In the case of lighting which takes a high surge current halogen la...

Page 9: ...he channels of the lighting controller are switched on 0V connection between controller and DP10000 broken or missing Interference on sound system Sensitive audio connections run too close to dimmer o...

Page 10: ...h terminal blocks Earthing system TT or TN C S Analogue input impedance 44 kW Control voltage 0 V fully off 10 V fully on Maximum load per channel 10 A or 2 3 kVA 230 V AC 2 3kVA corresponds to a resi...

Page 11: ...appliances and disposal is free of charge to the end user When replacing an existing appliance with a similar new appliance your retailer may take the old appliance for disposal STANDARDS The DP10000...

Page 12: ...ny attempts made to service or modify the unit then the warranty will be rendered void The product you buy may sometimes differ slightly from illustrations This warranty is in addition to and does not...

Reviews: