Output frequency (Hz)= X Frequency limit(Hz)
TRANSIMITTER
CONVERT PARTS
TM
26
Http: // www.flowmeter.cc
CONVERT
Low Cutoff%
1.0
<-ENT ESC->
2.0
4
3
Click “ ” and “ ”key to set
“Low Cutoff%”,Click “ ” show
confirm menu
1
2
Steps
Operation instructions
Interface show
Click “ ” into “Low Cutoff%”
Click “ ” key to confirm and return
configuration menu(click” ” give
up modify
Click “ ” three times from configuration menu to measurement
menu, also you can continue other operation.
Low Cutoff%
1.0
Max: 9.9
Min: 0.0
1.0
Low Cutoff%
1.0
Max: 9.9
Min: 0.0
2.0
Steps:
measurement mode
→
system
→
signal
→
Low Cutoff%
Steps:
measurement mode
→
system
→
Pulse Output
→
Freq Max(Hz)
8.) Small flow termination%(low %)
The parameters on the display and output are valid. When the traffic signal to terminate below
the low flow rate (unit%) of the settings to set the value of the The signal will be removed,
display and output to zero. The termination of the small percentage is relative to the scale in
terms of flow rate settings. Set As follows
9.) Frequency upper limit Hz
output frequency range of the instrument 100-5000Hz
Scale corresponding to the current flow of output frequency
the current flow rate (m3/h)
scale flow rate (m3/h)