Nitto Construction
- 23 -
5.2
Set-up and Writing-in of Measurement Parameters
・
Click [Parameters Set]
⑥
button in the initial screen of CTS-02V4-PC.
・
The dialog window as shown below will be displayed to input the measurement parameters
(See Fig.5.2-1).
・
All parameters in CTS-02V4 can be set using this dialog.
Fig.5.2-1 Dialog Window
<
CONCRETE
>
⑪
・
Select the measuring concrete is Normal or High Compressive by reference to Table 5.2-1.
・
The parameters are different in Normal or High Compressive concrete.
Table 5.2-1 Selection of Measuring Concrete
Object Meaning
Normal
Normal concrete
(10 N/mm
2
~
30 N/mm
2
)
High Compressive
High compressive concrete
(30 N/mm
2
~
150 N/mm
2
)
※
The mode and parameters for set-up are used for calculation of the actual index values.
⑪
⑭
⑮
⑫
⑬
Summary of Contents for CTS-02V4
Page 1: ...CTS 02V4 User Manual...