System Performance

  Feed Water Requirements

Daily production rate     42.8 L/d

    Feed water(3)

       Potable water

   (11.3 gpd)

    Feed pressure

       275 kPa, (40psi) to 552kPa (80psi)

Efficiency Rating(1)

   8.8%

    Feed temperature        1°C (33°F) to 38°C (100°F)

Recovery Rating (2)         18%

    Total dissolved solids     2,000 mg/L maximum

    Chlorine

       1.0 mg/L max.

(1)Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse

osmosis treated water under operating conditions that approximate typical daily usage.

(2)Recovery rating means the percentage of the influent water to the membrane portion of the system that is

available to the user as reverse osmosis treated water when the system is operated without a storage tank or when

the storage tank is bypassed.

(3)Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before

or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filter-

able cysts. The feed water must also be free of potential membrane foulants such as Iron, Hydrogen Sulfide and

maganese.

OWNER'S MANUAL

Performance Sheet

D

System Tested and Certified by NSF International against NSF/ANSI Standard 58 for the

reduction of the contaminants listed below. The concentration of the indicated substances in

water entering the system was reduced to a concentration less than or equal to the permis-

sible limit for water leaving the system, as specified in NSF/ANSI 58.

This system has been tested for the treatment of water containing pentavalent arsenic (also

known as As(V), As(+5), or arsenate) at concentrations of 0.30 mg/L or less. This system

reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be

used on water supplies containing a detectable free chlorine residual at the system inlet or on

water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment

with chloramine (combined chlorine) is not sufficient to ensure complete conversion of trivalent

arsenic to pentavalent arsenic.Please see the Arsenic Facts section of the Performance Data

sheet for further information.

Testing was performed under standard laboratory conditions, actual performance may vary.

Substance

Influent

Challenge
Concentration
(mg/L)

Average
Percent
Reduction

Maximum
Permissible Product
Water
Concentration
(mg/L)

Arsenic (pentavalent)

0.30+ 10%

98.2

0.025

Barium

10.0 +10%

>99.9

2.0

Cadmium

0.03+ 10%

94.8

0.005

Chromium
(Hexavalent)

0.3+ 10%

87.5

0.1

Chromium (Trivalent)

0.3+ 10%

96.8

0.1

Copper

3.0+ 10%

99.2

1.3

Floride

8.0+ 10%

96.7

1.5

Lead

0.15+ 10%

98.6

0.010

Selenium

0.10+ 10%

97.6

0.05

Radium 226/228

25pCi/L+ 1 0 %

80.0

5 pCi/L

Total Dissolved
Solids

750 +10%

96.4

1 8 7

Turbidity

11 +1 0 %   N T U

99.1

0.5

Cysts

80,000 3-4u/mL

99.99

7 # /mL

Summary of Contents for Sierra

Page 1: ...1 REVERSE OSMOSIS DRINKING WATER SYSTEM Owner sManual InstallationGuide 41840 McAlby Court Suite A CA Murrieta 92562 800 451 9343 Email sierra nimbuswater com ...

Page 2: ...r intervals The chart below gives a general replacement timetable For more accurate membrane filter replacement intervals the system should be tested for TDS by an authorized Nimbus dealer Instructions for cartridge replacement can be found in Section 10 of the Installation Guide Any significant change in performance of the system should be investigated promptly to avoid secondary damage or deteri...

Page 3: ...ng and service This reverse osmosis system contains a replaceable component critical to the effiency of the system Replacement of the reverse osmosis component should be with one of identical specifications as defined by the manufacturer to assure the same efficiency and contaminant reduction performance Use of non Sierra replacement parts will invalidate the warranty as set forth in Section F of ...

Page 4: ...ncentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permis sible limit for water leaving the system as specified in NSF ANSI 58 This system has been tested for the treatment of water containing pentavalent arsenic also known as As V As 5 or arsenate at concentrations of 0 30 mg L or less This system reduces pentavalent arsen...

Page 5: ... remove trivalent ar senic from water very well RO systems are very effective at removing pen tavalent arsenic A free chlorine residual will rapidly convert trivalent arsenic to pentavalent arsenic Other water treatment chemicals such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic A combined chlorine residual also called chloramine may not con vert al...

Page 6: ...yondthecontrolofthe Manufacturerarenotcoveredbythiswarranty IncidentalandConsequentialDamages TheManufacturerdoesnotassumeresponsibilityforpaymentofincidentalandconsequential damagesasaresultofthefailureofthisunittocomplywithexpressorimpliedwarranties suchaslosttime inconvenience damageto personalproperty lossofrevenue commerciallosses postage travel telephoneexpenditures orotherlossesofthisnature...

Page 7: ...ithstandardsink plumbingandproperuseofcommonhandandpowertools Improperlyinstalledsystemscouldresult inwaterdamageduetoleaksorflooding Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequate disinfection before or after the system 1 A Product water storage tank I Product water tubing 3 8 blue B Tank shut off valve J Reverse osmosis membrane filter C Tank tubing 3 8 white K C...

Page 8: ...fwarninglabel Self tapping mounting screws 2 Flatrubberwasher Grayrubbercone Faucet Kit not shown Tubing notshown 6 white 3 8 tubing 4 blue 3 8 tubing 4 green 1 4 tubing 4 yellow 1 4 tubing F The feed water connection assembly supplied with the Sierra system includes components which represent the most common under sink plumbing connections currently in use within the United States If these compon...

Page 9: ...ireanopenendwrench pliers orlong reachfaucetwrench Proceedtostep4 OptionB Toinstallthefeedadapterattheanglestop valve disconnectthefeedlineattheanglestop valve Thiswillusuallyrequireawrenchorpliers Withthisendofthewaterlinefree proceedtostep 4 4 Takethe1 4 feedconnectorvalvefromthepartskitandinstallitintothebrassfeedconnector adapter Useacrescentwrenchoropen endwrenchtotightenthevalveintotheadapte...

Page 10: ...le in the drain assembly 5 Tightenthesaddleboltsevenlyonbothsidesuntilthesaddlegripsthepipesnugly donot overtighten Fig 4 Inadditiontocommonhandtools thefollowingtoolsarerequiredfordrillingthroughthemost commonsinkmaterials 1 4 masonrydrillbit 1 porcelain cutter 1 hole saw Hole saw adapter 7 8 chassispunch Centerpunch Hint Specialcareshouldbetakenwhendrillingthefaucethole Acleanholecan becutinasho...

Page 11: ...nk and wipe the area clean Be sure all metal chips are removed as they can stainporcelainveryquickly Tile Sink or Counter 1 Followprocedures1 3underEnamel Porcelain CastIronSinkprocedures 2 Withthegentleuseofthecenterpunchandhammer breakuptheceramicdisktotheextent necessarytoremoveit Removetheceramicdisk 3 Use the 1 hole saw or wood drill to continue the hole through the wooden support Clear awayt...

Page 12: ... Inserttubingandfaucetassemblydownthroughthe sink hole 8 Positionthefaucettothedesiredhandleorientation Sliptheslottedwasherbetweenthewhiteplasticspacer andthesink Securelyhandtightenthemountingnut Hint The airgap tubing connection is located under the faucet handle By orientingtheair gapfromtheunderside of the sink your faucet handle should be correctlyoriented 9 Connectthewhite3 8 tubingtothedra...

Page 13: ...eunittoberemovedfromtheinstalledlocationforservicing Cutofftheexcess andfirmlyinsertthetubingintothecorrespondingyellowdrainconnectionlocatedonthemani fold 5 Extendthe3 8 bluetubingfromthefaucetunittothemanifold Leaveenoughslackinthe tubingtoallowtheunittoberemovedfromtheinstalledlocationforservicing Cutofftheexcess andfirmlyinsertthetubingintothecorrespondingblueproductwaterconnectionlocatedonthe...

Page 14: ...ent inordertoensuretankinternalcleanliness Also thecarbonfiltercartridge willreleaseasmallamountofcarbonfinesduringthefirsttankfulofflow Thisflushingprocedure willallowanysanitizerorcarbonfinestopassfromthesystem 2 Initialtankfillingwilltakeapproximatelytwoandonehalfhours basedonaveragefeed pressure Whenthetankisfull thewaterpressurewillhaverisentothepointwheretheauto maticshut offvalveinsidethema...

Page 15: ...properly 4 Alltubingconnections especiallypush inquickconnections arefullyinserted 5 Tubingconnectedbetweenthefaucetandthedrainsaddlefitting thefittingattachedtothesink drainpipe runs downhill tothedrain Thereshouldbenoloopsorplaceswherewaterwouldnot flowouttothedrain 6 Feedandtankvalvesareopen 7 Withinonetotwohoursafterinitialapplicationofwaterpressure checkagainforleaksespecially atthetank fauce...

Page 16: ...nnectorsuntilitsnapsintoplaceproperly 7 Turnonfeedwatershut offvalve 8 Turnontankshut offvalve Observesystemforanyleaks especiallyatnewlyreplaced cartridge 9 Closedispensingfaucetafterwaterstopsrunning 10 Ifreplacedcartridgewasapostcarbonoramembranefilter thesystemshouldbeflushedat leastonceasdescribedaboveunderSection9 TankSanitizing Tanksanitizingshouldbedoneeverytwelvemonthsaspartoftheregularsy...

Page 17: ...17 NimbusWaterSystems2003 PN103257 ...

Reviews: