7
3.2 Condition of distance
In consideration of the cooling
system of the machine and the
accessibility of service, there
must be free wall space on both
sides of the machine. To the
right 500 mm at a min i mum and
to the left 150 mm at a min i-
mum. To the ceiling there must
be at least 1000 mm and from
the rear point of the machine to
the back wall there must be at
least 100 mm. There must not
be any other objects in this area
either, such as pipes etc.
3.3
Mounting of feet and
levelling of machine
mount the 4 feet by fastening
them to the fl ange underneath
the machine by means of a 19
mm open-end wrench.
Place the machine on a plane
fl oor.
To level the machine, loosen
the lock nut on the appropriate
feet and adjust the height by
screwing the foot up or down.
Next cross-tighten the lock nuts
around the fl ange. It is impor-
tant that all 4 feet are in contact
with the fl oor.
3.4
Mounting of handle
Min. 500 mm
Min. 150 mm
0
°
C
°
85
°
80
°
60
°
Th
e machine is delivered
without feet mounted. Loosen
the machine from the pallet and
Mount the enclosed handles on
the machine by pressing them
into the suitable openings in the
cabinet.
3.5 Mounting of spacers
Mount the enclosed spacers at
the back of the machine.