background image

31

8 Technical 

Data

SOLAR BOOSTER PROGRAM

SOLAR BOOSTER

 

7-38E18H

SOLAR BOOSTER

 

7-58E18H

SOLAR BOOSTER

 

7-58E36H

SOLAR BOOSTER

 

7-58E36H

SOLAR BOOSTER

 

5-45D

SOLAR BOOSTER

 

5-52D

SOLAR BOOSTER

 

7-58D

SOLAR BOOSTER

 

7-58D

SOLAR BOOSTER

 

8

-103D

Item Nr.

107370260

107370270

107370274

107370276

107370050

107370055

107370070

107370075

107370080

Performance data :

 

Pump pressure  

[bar]

135

170

170

170

150

165

170

160

180

 Qiec 

 

[l/h]

810

1110

1110

1110

900

1000

1110

1110

1900

  Cleaning Impact  

 [kg-f

orce]

3.8

5.8

5.8

5.8

4.

5

5.2

5.8

5.8

10.3

 

Δ

 temp - (Full 

fl

 ow) 

[ºC]

19

14

28

42

73

65

76

74

49

 Heating 

power 

[kW]

18

18

36

54

80

80

115

115

115

 Ef

fi

 ciiency 

 

[%]

99

99

99

99

92

92

92

92

94

 W

eight 

(empt

y) 

[kg]

150

155

156

157

184

189

212

212

232

 

Max. sound power lev

el 

[dB(A)]

93

93

93

93

92

92

93

93

93

Motor / Pump :

 Nozzle 

type

530

680

680

680

550

600

680

700

1100

 Qmax 

 

[l/h]

875

1200

1200

1200

1020

1100

1200

1200

2000

 Pump 

type 

C3

C3

C3

C3

NA5

NA5

C3

C3

AR

 

Motor output power  

 [kW]

5.6

6.5

6.5

6.5

5.5

6.

7

6.5

6.5

11.0

 

Motor / pump 

[rpm]

1450

1450

1450

1450

1450

1450

1450

1450

1450

   Pump driv

e

Direct

Direct

Direct

Direct

Dir

ect

Direct

Direct

Direct

Direct

Connection requirements :

 V

oltage 

[V]

400

400

400

400

400

400

400

230

400

 

Current - Max. consumption 

[amp]

35,9/~3

39,4/~3

65,3/~3

91,2/~3

14/~3

15/~3

15/~3

25/~3

24/~3

 

Power consump

. (motor) 

 [kW]

18 + 5.8

18 + 7

.5

36 + 7

.5

54 + 7

.5

1.4 + 6.1

1.4 + 6.9

1.4 + 7

.5

1.4 + 7

.1

1.4 + 12.

7

 

Frequency                                 

[Hz]

50

50

50

50

50

50

50

50

50

 

Min. inlet w

ater pressure (f

ull 

fl

 ow) 

[bar]

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

Heating :

 Boiler 

type

W

ater tank

W

ater tank

W

ater tank

W

ater tank

EcoP

ower 5

EcoP

ower 5

EcoP

ower 7

EcoP

ower 7

EcoP

ower 7

 

Max. inlet temper

ature 

[ºC]

85

85

85

85

30

30

30

30

30

 

Max. outlet temper

ature  

[ºC]

85

85

85

85

99

99

99

99

99

 

Burner f

uel t

ype

Electricit

y

Electricit

y

Electricit

y

Electricit

y

Diesel

Diesel

Diesel

Diesel

Diesel

 

Fuel consumption @

Δ

T=40°C [kg/h]

-

-

-

-

4.

3

4.

8

4.

9

4.

9

4.

9

Available options :

 

Stainless steel cabinet

zzzzzzzzz

 Manual 

detergent

zzzzzzzzz

 R

emote 

control

zzzzzzzzz

 

1 x detergent

zzzzzzzzz

 

2 x detergent

zzzzzzzzz

 

Mechanical coin bo

x

zzzzzzzzz

 

Mechanical coin bo

x with detergent

zzzzzzzzz

   Low w

ater securit

y

zzzzzzzzz

 No-

Scale

zzzzzzzzz

 

Cold/w

arm selector switch

zzzz

 Pressure 

relief

zzzzzzzzz

 

Multiple machine connection bo

x

zzzzzzzzz

Summary of Contents for SOLAR BOOSTER 5-45D

Page 1: ...TER D EH Instruction manual 3 32 Betriebsanleitung 33 62 Manuel d Instructions 63 92 Gebruikershandleiding 93 122 Manual de instrucciones 123 152 Manuale di istruzioni 153 182 183 211 zemeltet si tmut...

Page 2: ...nal 16 4 2 Running the SOLAR BOOSTER 16 4 2 1 Starting up 16 4 2 2 Automatic start stop 17 4 2 3 Running with hot water 17 4 2 4 Double spray lance pressure regulation 18 4 2 5 Stop 18 4 2 6 Automatic...

Page 3: ...rust during opera tion therefore always hold the spray lance firmly with both hands Never try to clean clothes or footwear on yourself or other persons Operator and anyone in imme diate vicinity of th...

Page 4: ...n connect the machine to the mains supply The following points must be observed Check that the voltage stated on the data plate corresponds to your mains voltage Make sure that the power cord contains...

Page 5: ...uction service Section 4 describes how to use the high pressure hot water washer 2 2 Operation elements See illustration at the end of the manual 1 High pressure outlet quick coupling male 2 Main swit...

Page 6: ...ount the 4 feet by fastening them to the flange underneath the machine by means of a 19 mm open end wrench Place the machine on a plane floor To level the machine loosen the lock nut on the appropriat...

Page 7: ...see data plate Max water pressure 10 bar Max water inlet temp EH GH 85 C Max water inlet temp D G 30 C All SOLAR BOOSTER feature a water tank and no further protection against back flowing water into...

Page 8: ...nect the other end of the cable to an approved socket of a correct dimensioned main supply Make sure that the cable is properly guided and relieved between the fixed installation and the machine and t...

Page 9: ...rom the pump even water flow 5 In the case of a recently installed piping system or if the pipeline and the pump have been emptied in any other way the system should be vented by starting the pump and...

Page 10: ...from the system it may be necessary to vent the internal feed pump sepa rately The Nilfisk ALTO serv ice technician should perform this by loosening the centre screw on the feed pump see arrow 6 In t...

Page 11: ...e string only has one supply hose a and two string has an additional return hose b see illustration Please observe that in some countries only the one string system is approved The fuel hose s should...

Page 12: ...cock 3 to open position Danger of scalding Never dismount high pressure hoses at water temperatures above 50 C IMPORTANT Prior to dis mounting of the high pressure hose the machine should be cooled do...

Page 13: ...other accessory to ensure correct mounting before starting the machine 4 1 3 Spray handle accessories 4 1 4 Selection of spray lance 2 1 You may use a double spray lance as well as a single spray lanc...

Page 14: ...disinfec tants Dosage 1 8 Outlet point with detachable foam injector To be attached to the quick cou pling of the high pressure cock To be used in conjunction with foam lance for application of high...

Page 15: ...2 Push the green START push button 3 Check on the pressure gauge 6 that a pressure is being built up in the system and that the motor of the SOLAR BOOSTER stops within appr 20 seconds with the green S...

Page 16: ...d switch OFF the heating source SOLAR BOOSTER will moni tor the water temperature and regulate the heating source to provide the preset temperature On EH models with heating tanks on the suction side...

Page 17: ...C Prior to dismounting of the high pressure hose the machine should be cooled down After cooling down stop the machine and close the shut off cock Never detach the high pressure hose while the machin...

Page 18: ...STER EH model it will be possible to automatically stop the heating of the water in the water tank if the SOLAR BOOSTER has not been used in a period preset by the user 1 sec 9 hours The functions sys...

Page 19: ...n example it may be used for the cleaning of surfaces pressure which cannot stand a too powerful jet i e soft surfaces 5 3 Temperature Hot water significantly increas es the efficiency of the cleaning...

Page 20: ...of products specially developed for high pressure cleaning among other fields within Cleaning of vehicles ma chines stalls etc Disinfection Degreasing of workpieces Descaling The products are water ba...

Page 21: ...ces under high pressure 4 Rinse afterwards if neces sary To make sure that resi dual impurities are removed from the surface In connection with the working process the optimum cleaning will be reached...

Page 22: ...lt to reach places 3 Clean fragile areas such as motors rubber at lower pressure levels to avoid damage Task Accessories Method Vehicle body work Standard lance Detergent injection Curved lances and u...

Page 23: ...faces prior to treatment Wet sand blasting equip ment 1 Connect the sand blasting lance to the pressure washer and place the suction tube in the sand 2 Always wear protective equipment during sand bla...

Page 24: ...as laid down in the instructions 6 1 Hour counters 6 3 Water filter To avoid debris entering the high pressure pump a water filter fine is fitted at the water inlet Dependent on the purity of the wat...

Page 25: ...ump 1 Clean filter Unscrew filter cap 1 2 Clean replace fuel filter 2 3 Dispose of cleaning solu tion damaged filter in ac cordance with the disposal regulations 6 6 Disposable waste This high pressur...

Page 26: ...g all SOLAR BOOSTER models Symptom Reason Action Machine will not start A fuse has blown Change the fuse NO ERROR indication Power disconnected Connect power Fuses blow Installation does not Change to...

Page 27: ...lter clogged up Clean filter see sect 6 3 No working pressure Nozzle clogged up Clean nozzle see sect 6 4 No inlet water Check that the shut off cock of the water inlet is open Check that the water su...

Page 28: ...if no leakage is present Call Nilfisk ALTO service if oil is leaking or if water is mixed in the oil creamy white or transparent Overload cut out Overload or short circuit of Call Nilfisk ALTO service...

Page 29: ...Call Nilfisk ALTO service SOLAR BOOSTER If Option Low water security Check your water supply mounted lack of inlet open sufficient pressure pressure can be the reason Water Shortage Lack of water Che...

Page 30: ...Direct Direct Direct Direct Direct Direct Direct Connection requirements Voltage V 400 400 400 400 400 400 400 230 400 Current Max consumption amp 35 9 3 39 4 3 65 3 3 91 2 3 14 3 15 3 15 3 25 3 24 3...

Page 31: ...materi als or workmanship Usual wear and tear as well as misuse is not covered by the guarantee that repairs have not been carried out or attempted by other than Nilfisk ALTO trained service staff Dec...

Page 32: ...20 0 C 85 80 60 40 20 0 C 85 80 60 40 only EH 20 0 C 85 80 60 40 SOLAR BOOSTER D SOLAR BOOSTER EH 940...

Page 33: ...ilfisk Advance S A Torre D Ara Paseo del Rengle 5 Pl 10 08302 Matar Tel 3 4 902 200 201 Fax 3 4 93 757 8020 E mail mkt es nilfisk alto com SWEDEN ALTO Sverige AB Member of Nilfisk Advance Group Aminog...

Reviews: