14
NOTE!
Clean nipple of any impurities
each time the spray lance has
been dismounted, see illustra-
tion.
1. Pull forward the quick coup-
ling trigger (1) of the spray
handle.
2. Insert the nipple of the spray
lance (2) in the quick coup-
ling and release the trigger.
3. Pull forward the spray lance
or any other accessory to
ensure correct mounting
before starting the machine.
4.1.3
Spray handle -
accessories
4.1.4
Selection of spray
lance
2
1
You may use a double spray
lance as well as a single spray
lance with the machine.The
recommended nozzle size
of the lance is printed on the
data plate of the machine – i.e.
0530. The working pressure of
the machine can be reduced
by using nozzles with a wider
diameter.
Never use lances with smaller
nozzles (nominal value / diam-
eter) than stated on the data
plate.