Nilfisk-ALTO SOLAR BOOSTER 5-45D Instruction Manual Download Page 33

107319182 (10.2008)

http://www.nilfi sk-alto.com

FINLAND

Nilfi sk-Advance Oy Ab
Piispantilankuja 4
02240 Espoo
Tel.: +358 207 890 600
Fax: +358 207 890 601
E-mail: asiakaspalvelu.fi @nilfi sk.com

FRANCE

Nilfi sk-ALTO
ALTO France SAS
Aéroparc 1
19 rue Icare
67960 Entzheim
Tel.: (+33) 3 88 28  84 00
Fax: (+33) 3 88 30 05 00
E-mail: info.fr@nilfi sk-alto.com

GERMANY

Nilfi sk-ALTO
Division of Nilfi sk Advance
Guido-Oberdorfer-Str. 10
89287 Bellenberg 
Tel.: (+49) (0) 180 5 37 37 37
E-mail: info.de@nilfi sk-alto.com 

GREECE

Nilfi sk-Advance SA
8, Thoukididou str.
164 52 Argiroupolis
Tel.: +30 210 96 33443
Fax: +30 210 96 52187
E-mail: nilfi [email protected]

HOLLAND

Nilfi sk-ALTO 
Division of Nilfi sk-Advance BV
Camerastraat 9
3322 BB Almere
Tel.: (+31) 36 5460 760
Fax: (+31) 36 5460 761
E-mail: info.nl@nilfi sk-alto.com

HONG KONG

Nilfi sk-Advance Ltd.
2001 HK Worsted Mills Ind’l Bldg.
31-39 Wo Tong Tsui St.
Kwai Chung 
Tel.: (+852) 2427 5951
Fax: (+852) 2487 5828

HUNGARY

Nilfi sk-Advance Kereskedelmi Kft.
II. Rákóczi Ferenc út 10
2310 Szigetszentmiklos-Lakihegy
Tel: (+36) 24475 550
Fax: (+36) 24475 551
E-mail: info@nilfi sk-advance.hu

INDIA

Nilfi sk-Advance India Limited
349, Business Point, 
No 201,2nd fl oor, above Popular Car World, 
Western Express Highway, Andheri ( East), 
Mumbai - 400 069
Tel:  (+91) 22 321 74592

ITALY

Nilfi sk-ALTO
Divisione di Nilfi sk-Advance A/S
Località Novella Terza
26862 Guardamiglio (LO)
E-mail: d.puglia@nilfi sk-advance.it

JAPAN

Nilfi sk-Advance Inc.
1-6-6 Kita-shinyokohama, Kouhoku-ku
Yokohama, 223-0059
Tel.: (+81) 45 548 2571
Fax: (+81) 45 548 2541

MALAYSIA

Nillfi sk-Advance Sdn Bhd
Sd 14, Jalan KIP 11
Taman Perindustrian KIP
Sri Damansara
52200 Kuala Lumpur
Tel.: (+60) 3 603 6275 3120
Fax: (+60) 3 603 6274 6318

MEXICO

Nilfi sk-Advance de Mexico, S. de R.L. de C.V.
Prol. Paseo de la Reforma 61, 6-A2
Col. Paseo de las Lomas
01330 Mexico, D.F.
Tel: +52 55 2591 1002 (switchboard)
Fax: +52 55 2591 1002 ext. 229
E-mail: [email protected]

NORWAY

Nilfi sk-Advance AS
Bjørnerudveien 24
1266 Oslo
Tel.:  (+47) 22 75 17 70
Fax:  (+47) 22 75 17 71
E-mail: info.no@nilfi sk-alto.com

POLAND

Nilfi sk-Advance Sp. Z.O.O.
05-800 Pruszków
ul. 3-go MAJA 8
Tel.: +48 22 738 37 50
Fax: +48 22 738 37 51
E-mail: info@nilfi sk-alto.pl

PORTUGAL

Nilfi sk-ALTO
Division of Nilfi sk-Advance Lda.
Sintra Business Park
Zona Industrial Da Abrunheira
Edifi cio 1, 1° A
P2710-089 Sintra
Tel.: +35 808 200 537
Fax: +35 121 911 2679
E-mail: mkt@nilfi sk-advance.es

RUSSIA

Нилфиск

-

Эдванс

127015 

Москва

Вятская

 

ул

. 27, 

стр

. 7

Россия

Tel.: (+7) 495 783 96 02
Fax: (+7) 495 783 96 03
E-mail: info@nilfi sk.ru

SINGAPORE

Nilfi sk-Advance Pte. Ltd.
Nilfi sk-ALTO Division
40 Loyang Drive
Singapore 508961
Tel.: (+65) 6 759 9100
Fax: (+65) 6 759 9133
E-mail: sales@nilfi sk-advance.com.sg

SPAIN

Nilfi sk-ALTO
Division of Nilfi sk-Advance S.A.
Torre D’Ara
Paseo del Rengle, 5 Pl. 10
08302 Mataró
Tel.: (+3) 4 902 200 201
Fax: (+3) 4 93 757 8020
E-mail: mkt.es@nilfi sk-alto.com

SWEDEN

ALTO Sverige AB
Member of Nilfi sk-Advance Group
Aminogatan 18, Box 4029
431 04 Mölndal
Tel.: (+46) 31 706 73 00
Fax: (+46) 31 706 73 40
E-mail: info.se@nilfi sk-alto.com

TAIWAN

Nilfi sk-Advance Taiwan Branch
No. 5, Wan Fang Road
Taipei
Tel.: (+886) 227 002 268
Fax: (+886) 227 840 843

THAILAND

Nilfi sk-Advance Co. Ltd.
89 Soi Chokechai-Ruammitr
Viphavadee-Rangsit Road
Ladyao, Jatuchak, Bangkok 10900
Tel.: (+66) 2 275 5630
Fax: (+66) 2 691 4079

TURKEY

Nilfi sk-Advance Profesional Temizlik
Ekipmanlari Tic. A/S.
Necla Cad. NI.: 48
Yenisahra / Kadiköy
Istanbul
Tel.: (+90) 216 470 08 - 60
E-mail: info.tr@nilfi sk-advance.com

UNITED KINGDOM

Nilfi sk-ALTO 
Division of Nilfi sk-Advance Ltd.
Bowerbank Way
Gilwilly Industrial Estate, Penrith
Cumbria CA11 9BQ
Tel.: (+44) 1 768 86 89 95
Fax: (+44) 1 768 86 47 13
E-mail: sales.uk@nilfi sk-alto.com

USA

Nilfi sk-Advance Inc.
14600 21st Avenue North
Plymouth, MN 55447-3408
Tel.: (+1) 763 745 3500 
Fax: (+1) 763 745 3718
E-mail: [email protected]

VIETNAM

Nilfi sk-Advance Representative Offi ce
No. 51 Doc Ngu Str.
Ba Dinh Dist.
Hanoi
Tel.: (+84) 4 761 5642
Fax: (+84) 4 761 5643
E-mail: nilfi [email protected]
 

HEAD QUARTER

DENMARK

Nilfi sk-Advance Group
Sognevej 25
DK-2605 Brøndby
Tel.: (+45) 4323 8100
Fax: (+45) 4343 7700
E-mail: mail.com@nilfi sk-advance.com

SALES COMPANIES

ARGENTINA

Nilfi sk-Advance srl.
Edifi cio Central Park 
Herrera 1855, Offi ce 604 
Ciudad Autónoma de Buenos Aires
Tel.: (+54) 11 6091 1571
Fax:(+54) 11 6091 1575

AUSTRALIA

Nilfi sk-ALTO 
48 Egerton St.
P.O. Box 6046
Silverwater, N.S.W. 2128
Tel.: +61 2 8748 5966
Fax: +61 2 8748 5960
E-mail: info@nilfi skalto.com.au 

AUSTRIA

Nilfi sk-Advance GmbH
Metzgerstrasse 68
5101 Bergheim bei Salzburg
Tel.: 0662 456 400-0
Fax: 0662 456 400-34
E-mail: info.at@nilfi sk-advance.com

BELGIUM

Nilfi sk-ALTO a division of Nilfi sk-Advance n.v-s.a.
Riverside Business Park
Boulevard Internationalelaan 55
Bâtiment C3/C4 Gebouw 
Bruxelles 1070 Brussel 
Tel.: (+32) 2 467 60 40 
Fax: (+32) 02 466 61 50
E-mail: info.be@nilfi sk-alto.com

CANADA

Clarke Canada 
Part of the Nilfi sk-Advance Group
4080-B Sladeview Crescent, Unit 1
Mississauga, Ontario L5L 5Y5 
Tel.: (+1) 905 569 0266       
Fax: (+1) 905 569 8586 

CHINA

Nilfi sk-Advance (Shenzhen) Ltd.
Blok 3, Unit 130 1001 Honghua Road
Int. Commercial & Trade Center
Fuitian Free Trade Zone
518038 Shenzhen
Tel.: (+86) 755 8359 7937       
Fax: (+86) 755 8359 1063

CZECH REPUBLIC

ALTO Ceská Republika  s.r.o.
Do 

Č

ertous 2658/1

193 00 Praha 9
Tel.: (+420) 24 14 08 419
Fax: (+420) 24 14 08 439
E-mail: [email protected]

DENMARK

Nilfi sk-Advance A/S
Industrivej 1
9560 Hadsund
Tel.: +45 7218 2100
Fax: +45 7218 2105
E-mail: salg.dk@nilfi sk-alto.com

Nilfi sk-ALTO Food division
Division of Nilfi sk-Advance A/S
Blytækkervej 2
9000 Aalborg
Tel.: +45 7218 2100 
Fax: +45 7218 2099
E-mail: food.division@nilfi sk-alto.dk

Summary of Contents for SOLAR BOOSTER 5-45D

Page 1: ...TER D EH Instruction manual 3 32 Betriebsanleitung 33 62 Manuel d Instructions 63 92 Gebruikershandleiding 93 122 Manual de instrucciones 123 152 Manuale di istruzioni 153 182 183 211 zemeltet si tmut...

Page 2: ...nal 16 4 2 Running the SOLAR BOOSTER 16 4 2 1 Starting up 16 4 2 2 Automatic start stop 17 4 2 3 Running with hot water 17 4 2 4 Double spray lance pressure regulation 18 4 2 5 Stop 18 4 2 6 Automatic...

Page 3: ...rust during opera tion therefore always hold the spray lance firmly with both hands Never try to clean clothes or footwear on yourself or other persons Operator and anyone in imme diate vicinity of th...

Page 4: ...n connect the machine to the mains supply The following points must be observed Check that the voltage stated on the data plate corresponds to your mains voltage Make sure that the power cord contains...

Page 5: ...uction service Section 4 describes how to use the high pressure hot water washer 2 2 Operation elements See illustration at the end of the manual 1 High pressure outlet quick coupling male 2 Main swit...

Page 6: ...ount the 4 feet by fastening them to the flange underneath the machine by means of a 19 mm open end wrench Place the machine on a plane floor To level the machine loosen the lock nut on the appropriat...

Page 7: ...see data plate Max water pressure 10 bar Max water inlet temp EH GH 85 C Max water inlet temp D G 30 C All SOLAR BOOSTER feature a water tank and no further protection against back flowing water into...

Page 8: ...nect the other end of the cable to an approved socket of a correct dimensioned main supply Make sure that the cable is properly guided and relieved between the fixed installation and the machine and t...

Page 9: ...rom the pump even water flow 5 In the case of a recently installed piping system or if the pipeline and the pump have been emptied in any other way the system should be vented by starting the pump and...

Page 10: ...from the system it may be necessary to vent the internal feed pump sepa rately The Nilfisk ALTO serv ice technician should perform this by loosening the centre screw on the feed pump see arrow 6 In t...

Page 11: ...e string only has one supply hose a and two string has an additional return hose b see illustration Please observe that in some countries only the one string system is approved The fuel hose s should...

Page 12: ...cock 3 to open position Danger of scalding Never dismount high pressure hoses at water temperatures above 50 C IMPORTANT Prior to dis mounting of the high pressure hose the machine should be cooled do...

Page 13: ...other accessory to ensure correct mounting before starting the machine 4 1 3 Spray handle accessories 4 1 4 Selection of spray lance 2 1 You may use a double spray lance as well as a single spray lanc...

Page 14: ...disinfec tants Dosage 1 8 Outlet point with detachable foam injector To be attached to the quick cou pling of the high pressure cock To be used in conjunction with foam lance for application of high...

Page 15: ...2 Push the green START push button 3 Check on the pressure gauge 6 that a pressure is being built up in the system and that the motor of the SOLAR BOOSTER stops within appr 20 seconds with the green S...

Page 16: ...d switch OFF the heating source SOLAR BOOSTER will moni tor the water temperature and regulate the heating source to provide the preset temperature On EH models with heating tanks on the suction side...

Page 17: ...C Prior to dismounting of the high pressure hose the machine should be cooled down After cooling down stop the machine and close the shut off cock Never detach the high pressure hose while the machin...

Page 18: ...STER EH model it will be possible to automatically stop the heating of the water in the water tank if the SOLAR BOOSTER has not been used in a period preset by the user 1 sec 9 hours The functions sys...

Page 19: ...n example it may be used for the cleaning of surfaces pressure which cannot stand a too powerful jet i e soft surfaces 5 3 Temperature Hot water significantly increas es the efficiency of the cleaning...

Page 20: ...of products specially developed for high pressure cleaning among other fields within Cleaning of vehicles ma chines stalls etc Disinfection Degreasing of workpieces Descaling The products are water ba...

Page 21: ...ces under high pressure 4 Rinse afterwards if neces sary To make sure that resi dual impurities are removed from the surface In connection with the working process the optimum cleaning will be reached...

Page 22: ...lt to reach places 3 Clean fragile areas such as motors rubber at lower pressure levels to avoid damage Task Accessories Method Vehicle body work Standard lance Detergent injection Curved lances and u...

Page 23: ...faces prior to treatment Wet sand blasting equip ment 1 Connect the sand blasting lance to the pressure washer and place the suction tube in the sand 2 Always wear protective equipment during sand bla...

Page 24: ...as laid down in the instructions 6 1 Hour counters 6 3 Water filter To avoid debris entering the high pressure pump a water filter fine is fitted at the water inlet Dependent on the purity of the wat...

Page 25: ...ump 1 Clean filter Unscrew filter cap 1 2 Clean replace fuel filter 2 3 Dispose of cleaning solu tion damaged filter in ac cordance with the disposal regulations 6 6 Disposable waste This high pressur...

Page 26: ...g all SOLAR BOOSTER models Symptom Reason Action Machine will not start A fuse has blown Change the fuse NO ERROR indication Power disconnected Connect power Fuses blow Installation does not Change to...

Page 27: ...lter clogged up Clean filter see sect 6 3 No working pressure Nozzle clogged up Clean nozzle see sect 6 4 No inlet water Check that the shut off cock of the water inlet is open Check that the water su...

Page 28: ...if no leakage is present Call Nilfisk ALTO service if oil is leaking or if water is mixed in the oil creamy white or transparent Overload cut out Overload or short circuit of Call Nilfisk ALTO service...

Page 29: ...Call Nilfisk ALTO service SOLAR BOOSTER If Option Low water security Check your water supply mounted lack of inlet open sufficient pressure pressure can be the reason Water Shortage Lack of water Che...

Page 30: ...Direct Direct Direct Direct Direct Direct Direct Connection requirements Voltage V 400 400 400 400 400 400 400 230 400 Current Max consumption amp 35 9 3 39 4 3 65 3 3 91 2 3 14 3 15 3 15 3 25 3 24 3...

Page 31: ...materi als or workmanship Usual wear and tear as well as misuse is not covered by the guarantee that repairs have not been carried out or attempted by other than Nilfisk ALTO trained service staff Dec...

Page 32: ...20 0 C 85 80 60 40 20 0 C 85 80 60 40 only EH 20 0 C 85 80 60 40 SOLAR BOOSTER D SOLAR BOOSTER EH 940...

Page 33: ...ilfisk Advance S A Torre D Ara Paseo del Rengle 5 Pl 10 08302 Matar Tel 3 4 902 200 201 Fax 3 4 93 757 8020 E mail mkt es nilfisk alto com SWEDEN ALTO Sverige AB Member of Nilfisk Advance Group Aminog...

Reviews: