Solution System
53
Service Manual – SC351
Removal and Installation
Solenoid Valve Disassembly/Assembly
Disassembly
1 Place the machine on a hoisting system (if
available), then lift it Otherwise, drive the
machine on a level floor.
2 Make sure that the battery connector is
disconnected
3 Remove the cover and the solution and recovery
water tanks
4 Remove the solenoid valve power supply
connector (A)
5 Disconnect the hoses (B) and (C) under the
machine
6 Remove the screws (D) and recover the washers
7 Remove the solenoid valve (E) upwards
Assembly
8 Assemble the components in the reverse order of
disassembly and note the following:
◦
When assembling the solenoid valve (E),
the stamped arrow (F) must be tuned in the
direction of the solution flow as shown in the
figure.
B
D
C
E
A
E
F
P100808