Recovery System
33
Service Manual – SC351
Maintenance and Adjustments
Tank and Vacuum Grid Cleaning
1 Drive the machine to the appointed disposal
area
2 Check that the function selection knob is turned
to “0” and disconnect the battery connector
3 Remove the cover (A), clean and wash the cover
and the vacuum grid (B) with clean water
4 Drain the water from the tanks (C and D) and
clean them
5 If necessary, disassemble the grid (B) and
remove the float (E), than clean with care and
reinstall
6 Check the recovery tank cover gasket (F) for
integrity
Note:
The gasket (F) creates
vacuum in the tank that is
necessary for vacuuming the
recovery water.
7 If necessary replace the gasket (F) by removing
it from its housing (G) on the cover When
assembling the new gasket, install the joint (H)
in the area shown in the figure.
8 Check that the seating surface (I) of the gasket
(F) is clean and adequate for the gasket itself
9 Check the vacuum duct (J) and the gasket (K),
carefully clean if necessary
10 Reinstall the recovery tank cover (A)
A
C
I
I
D
B
E
J
F
G
K
H
P100789