Control System
27
Service Manual – SC3000
Function Electronic Board Alarm Codes (continued)
Other alarm indications on the display
Alarm Code
on the
display
Meaning
Condition
“---”
Water level signal missing or not as specified.
Pressure switch module output higher than 4.0 Volt.
“888”
Serial communication problem between dashboard electronic
board and function electronic board.
Signal missing or errors.
Off
Dashboard electronic board power supply missing.
Voltage between J1.1 and J1.4 less than 12 Volt.
Black-box: Record of Alarms, Battery Management Parameters (see page 32
- 33), Partial Hour Counter
The data indicated in the following table (ALARMS, BATTERY MANAGEMENT DATA) are stored in the non-
volatile memory of the electronic board and can be recalled and displayed by the external programmer (ITAL-
SEA UNIVERSAL PROGRAMMER, NILFISK P/N 9097297000) connect to port J9. For each stored datum
(event) the value HOURS.MINUTES of the TOTAL hour counter is associated when the alarm occurred. The
last 20 events are stored. When the total number of events is used up, the next events overwrite the older ones.
The data are shown on the programmer display, listed by decreasing order (starting from the latest) as: DA-
TUM - HOUR (1 per page). The UP and DOWN buttons are used to select 1 page at a time. All the stored paged
can be scrolled. The “info” button shows the DATUM - EVENT DESCRIPTION for the selected line.
DATUM
EVENT DESCRIPTION
Condition
G2
EEPROM error
See alarm code description
G3
General thermal protection
See alarm code description
G4
Blown F2 fuse
See alarm code description
G5
Wrong KEY sequence
See alarm code description
G6
No signal from BATTERY CHARGER
See alarm code description
G7
Battery undervoltage
See alarm code description
G8
Serial communication error with dashboard electronic
board
See alarm code description
G9
Battery voltage drop
See alarm code description
F2
Brush motor protection intervention
See alarm code description
F3
VACUUM SYSTEM overcurrent
See alarm code description
F4
DECK ACTUATOR position irregularity
See alarm code description
F5
VACUUM SYSTEM power section damage
See alarm code description
F6
PRESSURE SWITCH signal fault
See alarm code description
F7
VACUUM SYSTEM output short circuit
See alarm code description
F8
Function general relay fault
See alarm code description
t2
Drive system amperometric protection intervention
See alarm code description
t3
Electromagnetic brake not present
See alarm code description
t5
Drive system power section damage
See alarm code description
t6
Pedal input not admitted
See alarm code description
t7
Drive system overcurrent
See alarm code description
t8
Drive system relay fault
See alarm code description
GB-N
Time of continuous use with discharged batteries
“N” is the number of hours from the key switching ON and OFF
during the battery level is under 18,4 Volt for WET, 19,6 for
AGM. This event is not recorded if the above time is less than 10
minutes.
GC
Charging cycle interrupted before completion
Battery charger disconnection before PHASE IV (= with red or
yellow LED on)
GD-N
Charging phase duration
N = Number of hours from battery charger connection to
completion of PHASE II (red LED on) if < 4