Recovery System
57
Service Manual – SC3000
Troubleshooting
Trouble
Possible Causes
Remedy
The vacuum system motor does not turn
on
The wiring harness between function electronic board
(EB1) and vacuum system motor (M2) is damaged
Repair
The vacuum system motor carbon brushes are worn
Replace
The dashboard instrument electronic board (EB3) is
faulty
Replace
The vacuum system motor is faulty
Check the electrical input
Dirty water vacuuming is insufficient or
there is no vacuuming
The vacuum grid with automatic shut-off float is activated
because the recovery tank is full
Drain the recovery tank
The filter is dirty
Clean
The vacuum grid with automatic shut-off float is dirty
Clean
The tank cover is not correctly positioned
Adjust
The tank cover gasket is not efficient
Clean or replace
The vacuum system motor filter is dirty
Clean
The vacuum gaskets are damaged or do not match
perfectly
Repair or replace