USER MANUAL
ENGLISH
BA 451 - BA 451D - BA 531 - BA 531D
909 6748 000(3)2010-03 A
25
FUSE CHECK/REPLACEMENT
Disconnect the battery connector (12).
1.
Move aside the recovery water drain hose (16).
2.
Remove the battery charger cable (I, Fig. 8), if equipped, from the cable holder (J).
3.
Remove the screws (A) and carefully move aside the panel (B) by disengaging the grommet (K) from its housing on the panel
4.
(B).
Check/replace the following fuses:
5.
Brush deck fuse F1: (40 A)
C)
Vacuum system fuse F2: (30 A)
D)
Drive system fuse F3: (30 A) (*)
E)
Signal circuits fuse F4: (3 A)
F)
Brush/pad-holder release fuse F5: (20 A) (*)
G)
Pump fuse F6: (3 A) (*)
H)
Only for
(*)
BA 451D
and
BA 531D
Perform steps 1 to 4 in the reverse order.
6.
F G H
A
A
B
A
A
J
I
D
K
E
C
Figure 8
S311339
DETERGENT TANK CLEANING
(For machine with EcoFlex™ system)
Clean the detergent tank (45) according to the following procedure:
Drive the machine to the appointed disposal area.
1.
Open the cover (22) and check that the recovery tank (21) is empty, otherwise empty it with the drain hose (16). Close the
2.
cover (22).
Grasp the handle (41) and carefully lift the tank (40).
3.
Unscrew the plug and disconnect the hose (48) from the tank (45).
4.
Remove the tank by releasing it from the fasteners.
5.
Wash the tank in the appointed disposal area.
6.
Install the tank (45) and connect it to the hose (48).
7.
When the detergent tank has been drained, the EcoFlex™ system must be drained too (see the procedure in the following
8.
paragraph).
909 6748 000(4)2010-03 A.indb 25
909 6748 000(4)2010-03 A.indb 25
04/03/2010 13.56.14
04/03/2010 13.56.14
Summary of Contents for ecoflex BA 451