USER MANUAL
ENGLISH
BA 451 - BA 451D - BA 531 - BA 531D
909 6748 000(3)2010-03 A
23
TANK AND VACUUM GRID WITH FLOAT CLEANING, AND COVER GASKET CHECK
Drive the machine to the appointed disposal area.
1.
(Only for
2.
BA 451D
and
BA 531D
): Turn the ignition key (80) to “0”.
(Only for
BA 451
and
BA 531
): Turn off the machine by pressing the switch (71) and/or (73).
Open the cover (A, Fig. 6) to washing position (L).
3.
Wash with clean water the cover (A), the tanks (B and C) and the vacuum grid with automatic shut-off
fl
oat (D).
4.
Drain the water from the tanks with the hoses (16 and 17).
If necessary, release the fasteners (E) and open the grid (D), recover the
fl
oat (F), clean all the components and then reinstall
5.
them.
Check the tank cover gasket (G) for integrity.
6.
NOTE
The gasket (G) creates vacuum in the tank that is necessary for vacuuming the recovery water.
If necessary replace the gasket (G) by removing it from its housing (H). When assembling the new gasket, install the joint (I) in
the rear central area, as shown in the
fi
gure.
Check that the seating surface (J) of the gasket (G) is integral and adequate for the gasket itself.
7.
Check the compensation hole (K) for clogging, and clean it if necessary.
8.
NOTE
The hole (K), allowing to compensate the air in the cover air gap, contributes to create vacuum in the tank.
Close the cover (A).
9.
H
D
E
E
F
G
C
B
J
A
G
L
I
K
Figure 6
S311337
909 6748 000(4)2010-03 A.indb 23
909 6748 000(4)2010-03 A.indb 23
04/03/2010 13.56.13
04/03/2010 13.56.13
Summary of Contents for ecoflex BA 451