6FUXE6\VWHP&\OLQGULFDO
6HUYLFH0DQXDO±$GYDQFH&RQGRU;/1LO¿VN(5
0DLQ6FUXE'HFNDQG5LJKW6LGH6FUXE3UHVVXUH
The following conditions must be met for the Main Scrub Deck to apply the selected downward scrub
pressure:
The
Key Switch
must be on.
The engine must be running.
The scrub on mode must be selected on the
Dashboard Panel
.
The drive pedal must be activated (moved from the neutral position).
* PWM = Pulse Width Modulated
Component
Current - Amps
Coil Resistance - Ohms
L5
$PSV
RKPV
/
$PSV
RKPV
L7
$PSV
RKPV
Pressure Setting
L5 Coil Amp draw readings (± 10%)
1
DPSV
(varies with scrub setting selected)
3
Pressure Setting
L7 Coil Amp draw readings (± 10%)
1
WRDPSV
(all three scrub pressure settings)
3
L6
B-
B+ from
K1 Power Relay
B- OUTPUT
PWM*
TOUCH PAD
DASHBOARD PANEL
CB4
20A
ORN
L7
B+
B-
RED/VIO
DRIVER BOX
PIN J2-26
SCRUB PRESSURE
PROPORTIONAL DN
WHT/VIO
SCRUB CYLINDER
LOCK
PIN J2-4
PIN J2-24
YEL/BLU
ORN/RED
B- OUTPUT
B- OUTPUT
PWM*
L5
SCRUB PRESSURE
PROPORTIONAL UP
S1
KEY SWITCH
B1
Variable 12VDC PWM
12VDC
Variable 12VDC PWM