background image

Software Manual 

Control Panel for Pegasus Units

Models:  MD 421-P
  MD 

422-P 

  BW4-P

 

Software Manual …………………………………….. 

1-18

V. 5.02

EN

Summary of Contents for BW4-P

Page 1: ...Software Manual Control Panel for Pegasus Units Models MD 421 P MD 422 P BW4 P Software Manual 1 18 V 5 02 EN ...

Page 2: ...VIEW OF MAIN AND SUB MENUS 8 5 1 Content of the Info menu 9 5 2 Content of the Errors menu CAUSE REMEDY 9 5 2 1 Error List 9 5 3 Content of the Setup menu 11 5 3 1 Submenu setting 12 5 3 2 Submenu Language Units 12 5 3 3 Submnenu Installation 12 5 4 Content of Readings 13 6 UPGRADE FIRMWARE 14 6 1 Upgrade using USB Cable 14 6 2 Upgrade using IrDA Cable 16 6 3 Upgrade Controller Board 18 ...

Page 3: ...erated via the control panel see below illustration 1 OFF Button 1 switches OFF the unit 2 ON STANDBY Button 2 switches ON the unit 3 ERROR Error light indicator 3 4 NAVIGATION BUTTONS The four arrow navigation buttons 4 are used for navigation in the display menu Pressing the OK button activates the menu and confirms any activity displayed 5 DISPLAY 1 2 3 4 5 ...

Page 4: ...he active navigation buttons on the control board The arrows illustrate that it is possible to scroll up and down between the menus Scrolling to the right makes it possible to enter a value Set the value scrolling up or down to set the value higher or lower accordingly Confirm by pressing ok 2 A letter combination for easy reference in connection with service work will appear in the top right corn...

Page 5: ... Setup menu settings display EP If date and time is not set date and time will count from the pre set default date and time 2006 01 01 12 00 Date time EP Set date and time using navigation buttons Set date time 2006 01 01 12 00 Confirm by pressing OK button 3 2 Standby The start up display will look as the one below Nilfisk FOOD Pegasus 12 00 00 ...

Page 6: ...ning ERROR WARNING In case of an error ERROR will appear on the display screen Press the OFF button to switch of unit If the error remains when the unit is switched ON again please Press right arrow to see current error In case of a warning WARNING will appear on the display screen When a warning is detected the machine will either stop or run with limited performance until the cause of the warnin...

Page 7: ...nt of Main and Submenus The control panel contains the below main menu screen displays Scroll between the menus using the navigation buttons Each main menu contains submenus which will be described subsequently Info i A Errors B Setup C Readings R ...

Page 8: ...ssword CA 2 Settings E Standard pressure ER Auto off delay EZ Date Time EP 3 Languages units F Language FA Units FB 4 Communication I Firmware Upgrade by cable IC Firmware Upgrade by infrared ID 5 Installation K Install Password KA 4 Readings R Pump state RA Pump top pres RB Pump top temp RC Supply pressure RD Supply temp RE Flow Status RF ...

Page 9: ... in First out principle 5 2 1 Error List Error Cause Remedy C1 Inverter Error 1 Frequency inverter in error state 1 Switch off the power on the service switch Wait 180 sec Switch on the unit again If error still occurs please contact your local service technician C2 Low Supply Pressure 1 Insufficient water supply 1 Secure sufficient water supply pres sure 2 Check inlet filter for impurities rinse ...

Page 10: ...r local service technician C20 Low Sensor Signal P Pump top 1 Pressure signal from pumptop sensor out of range 1 Press off button 2 If error reoccurs contact your local service technician C21 Low Sensor Signal T Pump top 1 Temparature signal from pumptop sensor out of range 1 Press off button 2 If error reoccurs contact your local service technician C22 Low Sensor Signal P Inlet 1 Pressure signal ...

Page 11: ...ton 2 If error reoccurs contact your local service technician C43 Sensor Load Flow sensor 1 Supply voltage for flow sensor too low 2 Flow sensor using too much current 1 Press off button 2 If error reoccurs contact your local service technician C45 Inverter Module temp 1 Water consumption too high 2 Ambient temperature too high 1 Lower the load for inverter 2 Lower the ambient temperature C46 Inve...

Page 12: ...ay OFF EZ Delay OFF Set auto off EZA OK 2006 01 01 12 00 Date time EP Set date time 2006 01 01 12 00 Set date and time 5 3 2 Submenu Language Units Languages L F units English Language FA English Language FAA OK Metric Units FB Imperial Units FBA OK 5 3 3 Submenu Installation Installation K For the use of authorised Local service technician only ...

Page 13: ...13 110007944 EN Software Manual_Pegasus Readings R Pump state 82Hz RA 24bar Outlet pres RB 29 C Water temp RC 2 5 bar Supply pressure RD No Flow Flow status RF 5 4 Content of Readings ...

Page 14: ...is Upgrade Ready Power Cycle and Start PC App 5 Disconnect display from usb cable and connect it again Power cycle 6 Make sure the Green ON led and the red OFF led at the display is both on display is blank 7 Startup PC program FWU200 exe can be downloaded from Nilfisk Food website 8 Window should be looking like this 9 Press Browse button 10 Select the file you will use for upgrade Software File ...

Page 15: ... less than 1 minute 16 When the upgrade is complete the FWU tool should be looking like this Button turns Green and text changes to DONE NEW 17 Now the display is upgraded 18 To verify software version in display in the menu go to Info Machine info 19 Here you will find display software version and control software version SW ID Display software HW ID type of device CT ID Controller board software...

Page 16: ...turn it on again Power cycle 5 Make sure the All three led s are on Green ON red ERROR and red OFF and the display is blank 6 Connect Irda module Item No 110001558 to PC USB port 7 Place Irda module on display module like this 8 Startup PC program FWU200 exe can be downloaded from Nilfisk Food website 9 Window should be looking like this 10 Press Browse button 11 Select the file you will use for u...

Page 17: ...rogram must go to the end before the upgrade is complete less than 1 minute 17 When the upgrade is complete the FWU tool should be looking like this Button turns Green and text changes to DONE NEW 18 Now the display is upgraded 19 To verify software version in display in the menu go to Info Machine info 20 Here you will find display software version and control software version SW ID Display softw...

Page 18: ...PC 6 Power on inverter by using service switch AWARE OF HIGH VOLTAGE IN INVERTER 7 Start up Firmware upgrade program Can be downloaded from Nilfisk FOOD web 8 Click browse to select upgrade file hex Can be downloaded from Nilfisk FOOD web 9 Click in Serial port up down to select the com port for USB cable if comport is not showing press refresh button 10 If necessary change inverter ID to match In...

Page 19: ...sus 13 Power off unit using service switch wait for unit to discharge approximately 5 min 14 Disconnect the usb cable from inverter 15 Connect the display to modbus connector again 16 Mount the lit of the inverterbox 17 Turn unit back on ...

Page 20: ...No 110007944 June 2021 Printed in Denmark 2014 All rights reserved Distributor ...

Reviews: