FORM NO. 56043025 / BA 700, 800, 1000 / 28LX, 32LX, 38LX / 280HD, 320HD, 380HD -
13
SOLUTION SYSTEM
K
J
FIGURE 3
______________________________________________________________________________________________
SOLUTION CABLE REPLACEMENT - BA 700 / 28LX / 280HD
1
Drain the solution tank at a designated
“DISPOSAL SITE”.
2
See Figure 3. Disconnect Ball Joint
(I)
from the valve arm. Be careful not to
lose the bushings.
3
Remove Ball Joint
(I)
from the cable,
then remove the cable from the chassis
cable mount, (note the cable position in
the mount).
4
See Figure 4. Remove Panel
(J)
.
5
Disconnect Ball Joint
(K)
from the lever,
and then remove the balljoint from the
cable.
6
Remove the cable from the control
handle cable mount, (note the cable
position in the mount).
7
Before removing the cable, take note of
the cable routing. Pull the cable up and
out through the control handle.
8
Follow steps 1-8 in reverse order to
reassemble. Test the new cable for
proper operation before reinstalling the
panels.
FIGURE 4