FORM NO. 56043025 / BA 700, 800, 1000 / 28LX, 32LX, 38LX / 280HD, 320HD, 380HD -
31
VACUUM SYSTEM
______________________________________________________________________________________________
TROUBLESHOOTING
______________________________________________________________________________________________
Problem:
Machine will not pick up water, water flows around ends of squeegee
Possible Cause & Remedy:
1
Plug for recovery tank drain hose not sealing air-tight — install plug properly or replace if damaged.
2
Recovery tank cover not installed properly — push cover down all the way, so it seals air-tight against the top of the
tank.
3
Damaged gasket on recovery tank cover — replace gasket.
4
Low battery voltage — charge or replace batteries.
5
Vacuum motor defective — repair or replace vacuum motor.
______________________________________________________________________________________________
Problem:
Water in vacuum motor
Possible Cause & Remedy:
1
Operator using high-sudsing detergent — use low-sudsing detergent or add a defoaming chemical to the recovery
tank.
2
Vacuum leak in recovery tank drain hose or plug — replace hose or plug.
3
Vacuum shut-off float ball not closing — clean or replace float ball and cage (mounted on recovery tank cover).
______________________________________________________________________________________________
Problem:
Float closes before tank is full
Possible Cause & Remedy:
1
Foam in recovery tank — use low-sudsing detergent or add a defoaming chemical to the recovery tank.
2
Cage around vacuum shut-off float clogged — disconnect hoses from recovery tank cover, remove the cover and
clean or replace the float cage.