G ENERAL MACHINE TROUBLESHOOTING
FAULT CODE DISPLAY
Any fault codes detected by the controllers will
be displayed on the control panel display as they
occur. If more than one error exists, the display will
sequence through the error codes at one-second
intervals. The error will display as a mechanical
wrench symbol
followed by a four-digit code.
Fault codes are displayed as X-YYY, where
X = system number (1: main board, 2: power
module, 3: drive controller)
YYY = fault code number
For example,
1-101
would be solution
solenoid valve – short.
C2 Active Fault Code
C24 Critical Fault Indicator
C25 Fault Code (Critical)
Fault Code
Description
E2 Main Controller Faults
1-001
K1 Coil Open
1-002
K1 Coil Short
1-003
K1 Contact Weld
1-010
CAN Bus 0
1-011
CAN Bus 1
1-101
L1 Short
1-102
L2 Short
1-103
H2 Short
1-104
LP1,2 Short
1-105
H1 Short
1-106
M8 Short
1-107
M9 Short
1-201
Level Sensor
1-560
EEPROM Con
fi
guration
1-561
EEPROM Options
1-562
EEPROM Sys Values
1-563
EEPROM Fault Log
1-564
EEPROM User Key List
1-565
EEPROM Impact Log
Fault Code
Description
E3 Power Module Faults
2-001
E3 Timeout
2-011
Precharge Fail
2-012
K2 Overload
2-013
K2 Contact Weld
2-014
K2 Contact Open
2-017
OverVolt Cutoff
2-018
UnderVolt Cutoff
2-021
M1 Open
2-022
M2 Open
2-023
M3 Open
2-024
M4 Open
2-025
M5 Open
2-026
M6 Open
2-027
M7 Open
2-028
M10 Open
2-031
M1 Overload
2-032
M2 Overload
2-033
M3 Overload
2-034
M4 Overload
2-035
M5 Overload
2-036
M6 Overload
2-037
M7 Overload
2-038
M10 Overload
2-041
M1 Overcurrent
2-042
M2 Overcurrent
2-043
M3 Overcurrent
C2
C25
C24
4/2016
A - 31
56091168 - SC6000
ENGLISH - A