FILLING THE SOLUTION TANK
See Figure 4.
Fill the solution tank with a maximum of 50 gallons (190 Liters) of cleaning solution. Do not
fi
ll the solution tank above 5 cm (2
inches) from the bottom of the Solution Fill
(32)
. The solution should be a mixture of water and the proper cleaning chemical for the job. Always
follow the dilution instructions on the chemical container label.
NOTE:
EcoFlex machines can either be used conventionally with detergent mixed
in the tank or the detergent dispensing system can be used. When using the detergent dispensing do not mix detergent in the tank, plain water
should be used.
CAUTION!
Use only low-foaming, non-
fl
ammable liquid detergents intended for machine application. Water temperature should not
exceed 130 degrees Fahrenheit (54.4 degrees Celsius)
FIGURE 4
2"
(5cm)
SOLUTION TANK INDICATOR
See Figure 5.
The solution tank has a level sensor with four measurement points. The Solution Level Indicator
(C4)
displays the level (1-4) of the
solution in the tank. Once the tank is empty the Solution Empty Indicator
(C26)
will
fl
ash on the display.
FIGURE 5
C4
C26
A - 16
SC6000 - 56091168
4/2016
INSTRUCTIONS FOR USE