raulic S ste
0
Service Manual – SC8000
lectrical Sc e atic
lectrical Circuit escri tion
For the actuators to lower the scrub deck and squeegee, the
Driver Box
must receive a signal from the
Dashboard Panel
via the CAN Bus that the Operator has actuated the scrub system.
For the vacuum fan to run, the
Driver Box
must receive a signal from the
Drive Pedal Sensor R1
that the
drive pedal has been moved from the neutral position.
The
Hydraulic Oil Temp Sender R2
must be within the correct resistance range that indicates the hydraulic
oil is within the acceptable temperature range. Note that
R2
has a variable resistance to ground, 12 to 500
ohms. The voltage when active is 0.16-2.24 volts.
The
Hydraulic Filter Switch S4
PXVWEHRSHQWRLQGLFDWHWKDWWKHK\GUDXOLFÀOWHULVQRWSOXJJHG
Fuse, 100A
Relay, Power
Dashboard Panel
Driver Box
J2-23 (VACC5)
J2-12 (VACC4)
J2-8
J2-5
J2-6
J2-22
J2-10
J2-7
J2-24
J2-26
J2-4
J2-3
J2-2
CB4
Circuit Breaker, 20A
K1
Battery
12 VDC
F1
Circuit Breaker, 15A
CB6
CB5
Circuit Breaker, 10A
Vacuum Fan S1
Squeegee Down S2
L1
L2
Squeegee Up S3
L3
Valve, Main Solution
L10
Valve, Right Solution
L11
Scrub Brush S4
L4
Scrub Pressure Proportional Up (S7)
L7
Scrub Pressure Proportional Down (S5)
L5
Scrub Cylinder Lock (S6)
L6
Side Scrub Lift (S9)
L9
Side Sweep/Scrub (S8)
L8
B1
3
B
Ignition_KeyPos
J1-12
S1
Switch, Ignition
J1-3 CAN +
J1-2 CAN -
J1-19
J1-32
J1-18
J6-3 CAN +
J6-1 (B+)
J6-2 (B-)
J6-4 CAN -
Sender, Hydraulic Oil Temp.
Twisted Pair
Twisted Pair
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
87
30
2
1
2
1
2
R2
Switch, Hydraulic Filter
(closes when the hydraulic filter is plugged)
1
2
S4
J2-1
K1
Relay, Power
Bat -
Bat -
Bat -
Bat -
Bat -
Bat -
Bat -
Bat -
Bat -
Bat -
Bat -