20
W
A L L
M
O U N T E D
P
R O G R A M M A B L E
I R K
E Y P A D
S
Y S T E M
Erasing a Single IR Command
If you make a mistake, you can erase just a sin-
gle key anytime by following these steps:
1. Press the PROGRAM button. The PROGRAM
LED, the IR/SEQ LED and the PAGE LED light
up red.
2. Press and hold the ERASE button until all the
PROMPT LEDs light up, then release. The PRO-
GRAM LED begins to flash, warning you that
you are about to erase.
3. Select the Page, then the Key that corresponds
to the address of the IR command that you wish
to erase. This erases any IR code stored at that
address.
4. To exit the Program mode, press the PROGRAM
button (the PROGRAM LED will go out).
Building Sequences to Automate
Any System
Planning the Sequence
Begin by writing down the address (Page, Key)
of the key which will trigger the sequence.
Sometimes, it helps to write a note describing
the function of the command. A sequence can
have a maximum of ten steps. See
Figure 17
.
NOTE: The power command for the preampli-
fier/receiver is never manually programmed
into a sequence. The IntelliPad’s Auto Power
Insert feature is enabled via the jumper labeled
Status Feedback.
System
System
Tuner
Tape
CD
Tuner
Tuner
Play
Stop
Pause
Tuner Input
Preset Station
Tape Deck
CD Player
Figure 17
Planning a sequence
TRIGGER
1
2
3
4
5
6
7
8
9
10
PAGE
KEY
NOTES
NUMBER
DS00154A/IntelliPad 2/5/99 4:32 PM Page 20