Table specifications

Dimension

Details

Width

887 mm (35 inches) (not including wheel position)

Depth

600 mm (24 inches) (not including wheel position)

Table height range

725 mm to 1205 mm (29 inches to 47 inches)

Monitor Support Arm radius

1.

514 mm (20 inches)

Monitor mount type

VESA MIS-D, 75, C (hole pattern: 75 mm x 75 mm)

Monitor Support Arm load

3 kg (6.6 lbs) to 5 kg (11 lbs)

Table weight

53 kg (116.8 lbs)

Maximum load on table

65 kg (143.3 lbs)

Total mass

118 kg (260.1 lbs)

The table provides wheelchair accessibility.

Environmental considerations (ambient)

Do

NOT

operate the table in an environment that exceeds the environmental limits.

Status

Temperature

Relative Humidity
(Non-condensing)

Atmospheric
Pressure

Normal use

+10°C to +40°C

75% (maximum)

70kPa to 106kPa

1. The radius is the maximum distance that the Monitor Support Arm extends beyond the width of the table.

Guidance and manufacturer declaration – electromagnetic
immunity

Immunity test

IEC60601 compliance
test level

Electromagnetic environment-guidance

Electrostatic
discharge
IEC61000-4-2

±6 kV contact
±8 kV air

Floors should be wood, concrete or ceramic tile. If
floors are covered with synthetic material, the
relative humidity should be at least 30%.

Electrical fast
transient/burst
IEC61000-4-4

±2 kV for power supply
lines
±1 kV for input / output
lines

Mains power quality should be that of a typical
commercial or hospital environment.

Surge
IEC61000-4-5

±1 kV line to line
±2 kV line to earth

Mains power quality should be that of a typical
commercial or hospital environment.

Voltage dips, short
interruptions and
voltage variations
on power supply
lines
IEC61000-4-11

<5% U

T

(>95%dip in U

T

)

for 0.5 cycle

40% U

T

(60% dip in U

T

)

for 5 cycles

70% U

T

(30% dip in U

T

)

for 25 cycles

<5% U

T

(>95% dip in U

T

)

for 5 seconds

Mains power quality should be that of a typical
commercial or hospital environment.

Power frequency
(50/60Hz)
Magnetic field
IEC61000-4-8

3 A/m

Power frequency magnetic fields should be at levels
characteristic of a typical location in a typical
commercial or hospital environment.

Note: UT is the AC mains voltage prior to the application of the test level.

Guidance and manufacturer declarations - electromagnetic
emissions

Emissions test

IEC60601
compliance
test level

Electromagnetic environment-guidance

RF emissions
CISPR 11

Group 1

The Optos Table uses RF energy only for its internal function.
Therefore, its RF emissions are very low and are

NOT

likely to

cause any interference in nearby electronic equipment.

RF emissions
CISPR 11

Class B

The Optos Table is suitable for use in all establishments,
including domestic establishments and those directly
connected to the public low-voltage power supply network that
supplies buildings used for domestic purposes.

Harmonic emissions
IEC61000-3-2

Class A

Voltage fluctuations/
flicker emissions
IEC61000-3-3

Pst
Dmax

Operations

The following procedures provide more information about using your table.

Adjusting the table height

WARNING

Ensure the cables are

NOT

pulled while the table height is being adjusted.

l

Select

to move the table up.

l

Select

to move the table down.

Contact us

Optos, Inc

Tel: 800-854-3039
[email protected]

Optos plc

Tel: +44 (0) 1383 843 300
[email protected]

Optos Australia

Tel: +61 8 8444 6500
[email protected]

Visit optos.com to find your local contact details.

Moving the table

The table has lockable wheels to prevent it moving during use.

1.

Remove all equipment from the table. Refer to the specific equipment instructions for details.

2.

Lower the height of the table to its lowest position for optimal stability and unobstructed view.

3.

Unplug the table mains cable from the wall socket.

4.

Place all cables on the table. Ensure there are no trailing cables.

5.

Pull the wheel lever up to unlock the wheel. Repeat for each wheel.

6.

Carefully move the table to its new location.

7.

When in position, push the wheel lever down to lock the wheel. Repeat for each wheel.

8.

Ensure the table works as expected.

General cleaning

CAUTION

Be careful

NOT

to damage the table or equipment when cleaning.

The table does not require cleaning before each use.
In a medical environment, if any part of the table or equipment becomes dirty or soiled with bodily fluids,
follow the general cleaning procedures and your internal clinic or hospital decontamination procedures.

Adjust the arm tension

To adjust the Monitor Support Arm tension, with a monitor fitted, follow these steps:

1.

Bend the main arm downwards to expose the bolt access cover.

2.

Remove and retain the access cover.

3.

Using an Hex key (4mm) turn the bolt as required.

a.

Turn the bolt clockwise to increase the tension and prevent the arm dropping.

b.

Turn the bolt anti-clockwise to decrease the tension and prevent the arm rising.

4.

Refit the access cover.

Adjust the monitor mount plate

To adjust the monitor mount plate tension follow these steps:

1.

Using an Hex key (4mm) turn the tension bolt either way as required:

a.

Turn "+" to increase tension.

b.

Turn "-" to decrease tension.

Summary of Contents for Optos Table

Page 1: ...le Ensure allwheels are unlocked before moving the table EMC safety CAUTION In order to provide reasonable interference protection against radio communication services this device has been tested and complies with 47 CFR Part 15 Sub Part Bof the FCC U S A rules and IEC EN 60601 1 2 standard requirements at the premises of a typicaluser and the CISPR11 standard emission limits CISPR11 Group 1 Class...

Page 2: ...ions are very low and are NOTlikely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class B The Optos Table is suitable for use in allestablishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Harmonic emissions IEC61000 3 2 Class A Voltage fluctuation...

Page 3: ...rese de que todas las ruedas estén desbloqueadas antes de mover la mesa Seguridad de CEM AVISO Afin de brindar una protección razonable contra interferencias de servicios de comunicación de radio este dispositivo se ha sometido a pruebas y cumple con los requisitos de la normas 47 CFR Sección 15 Subsección Bde las reglas de la FCC EE UU y CEI EN 60601 1 2 en las instalaciones de un usuario estánda...

Page 4: ...os electrónicos cercanos Emisiones de RF CISPR 11 Clase B Eluso la mesa Optos está indicado en todos los entornos incluido eldoméstico y aquellos directamente conectados a la red de suministro eléctrico pública de baja tensión que suministra electricidad a los edificios para usos domésticos Emisiones de armónicos IEC 61000 3 2 Clase A Fluctuaciones de voltaje emisiones de parpadeo según IEC61000 3...

Page 5: ... Sécurité en matière de compatibilité électromagnétique EMC PRÉCAUTION Pour assurer une protection raisonnable contre les interférences aux services de radiocommunication cet appareila été testé et reconnu conforme aux exigences de la norme 47 CFR paragraphe 15 sous article Bde la réglementation de la FCC États Unis et de la norme CEI EN 60601 1 2 dans les locaux d un utilisateur typique et aux li...

Page 6: ...sation dans tous les établissements y compris les établissements domestiques et les établissements directement rattachés au réseau d alimentation publique à basse tension quialimente les bâtiments utilisés à des fins domestiques Émissions d harmoniques IEC61000 3 2 Classe A Variations de tension émissions scintillement IEC 61000 3 3 Pst Dmax Opération Les procédures suivantes fournissentdeplus amp...

Page 7: ...bela Segurança EMC CUIDADO Para oferecer proteção razoávelcontra interferência comrelação a serviços de comunicação via rádio este dispositivo foitestado e está emconformidade com a regra CFR 47 Parte 15 Subparte Bda FCC EUA e comos requisitos da norma IEC EN 60601 1 2 nas instalações de umusuário típico e de acordo comos limites de emissão da norma CISPR11 CISPR11 Grupo 1 Classe B Embora emconfor...

Page 8: ...devemcausar nenhuma interferência emequipamentos eletrônicos nas proximidades Emissões RF CISPR 11 Classe B Amesa Optos é adequada para uso emtodos os tipos de estabelecimentos inclusive ambientes domésticos e outros emque haja conexão direta à rede elétrica pública de baixa tensão para alimentação de energia para fins domésticos Emissões harmônicas IEC61000 3 2 Classe A Flutuações de tensão emiss...

Reviews: