JAA79351-R.3670.A
- A34 ・ AF-S DX55-200/4-5.6G -
AF-S 55-200 inspection and adjustment program (J18386)
The below hardware requirements are necessary for installing the program on a computer.
Ensure them before installation.
PC
IBM PC/AT compatible
OS
Windows XP Home Edition, Windows XP Professional, Windows 2000,
Windows Millennium Edition (Me), Windows 98 Second Edition (SE),
Windows 98,
CPU
Pentium
Ⅱ
266MHz
~
Pentium
Ⅳ
2GHz
RAM (Memory)
32MB or more
HD
6 MB-or-more free space is necessary when installation
Monitor resolution 800×600 or more pixels
Interface
Serial interface
※
USB interface cannot be used.
As long as the above requirements are met, either desktop or notebook PC is available.
Preparation for inspection & adjustment of main PCB
●
In case of replacing the main PCB, SWM unit or MR encoder unit, be sure to make the necessary
adjustments as follows:
1. Adjustments
・
Adjust the MR duty
・
Adjust the driving frequency and motor control (including Focus preset adjustment)
2. Equipment and tools to be required
・
Single output rated voltage power supply: 1 unit ( 6.0V 3.0A)
・
Oscilloscope: 1 unit
For adjusting the MR duty, the driving frequency and motor control
・
AF-I communication box (J15306-1): 1 unit
・
AF-I communication adapter (J15307): 1 unit
● When the main PCB is replaced, be sure to perform
“3. READING AND REWRITING OF EEPROM
DATA” then “3. WRITING OF THE FIXED VALUES”.
Changed page
△
×3
[8. Writing of EEP-ROM Fixed Values]
△(
Revision
)
△(
Deletion
)
December. 19. 2006
, Inspection of Lens Driving Time
△(
Addition
)
INC