JAA79351-R.3670.A
- A19 ・ AF-S DX55-200/4-5.6G -
⑦
Rotate the micrometer (X, Y) so that the shape on the monitor become "A" of Fig.1.
Note
)
Moving up the holder changes the shape on the monitor, so make an adjustment by considering this
change.
⑧
When the shape becomes "A" of Fig. 1, tighten 3 screws of the 4th lens-group chamber, move up the holder-
moving lever slowly to lock, then remove the zoom fixed base and spacer D from the alignment equipment.
⑨
If there is no problem with WIDE side, set the zoom ring to TELE (200 mm) and conform that the shape is
like "A" of Fig.1.
⑩
If the shape is not like "A" of Fig. 1 at TELE (200 mm) side, set the lens to WIDE (55 mm) side again. Go
back to the previous
⑥
and loose the screw of the 4th lens-group chamber, then make an adjustment until
the shape becomes "A" of Fig. 1 at TELE (200 mm) side in
⑨
, too.
⑪
Turn the monitor, LINE GENERATOR, and MEGALIGHT 100 each to OFF, and remove the lens from the
alignment equipment.
Micrometer for X-axis
Micrometer for Y-axis
INC