61
EN
10-364
8.2. Legend LED display
LED
Status
Symbol
Indication
green
is on (during 3 s)
G
• transponder card recognized
• access granted
flashing
G
• programming in programming mode is possible using infrared remote
control or master transponder
red
is on (during 3 s)
R
• transponder card not recognized
is on (during 2 min)
R
blocking time after:
• third time a wrong master code has been entered with the infrared remote control
• third time a wrong master transponder has been used
• third time a wrong transponder has been used
flashing
R
• possible to delete in the programming mode via master transponder
orange
is on
O
• manual programming mode via master transponder
• all memory locations have been assigned
flashing
O
• manual programming mode via master transponder
• only one memory location available
flashing
• error indication when starting the device
Run/Prog key
is on
• programming mode of the installation is switched off
flashing
• programming mode of the installation is switched on
8.3. Legend confirmation tones
Tone
Symbol
Indication
short confirmation tone
infrared remote control confirms push of the key with a short key confirmation
tone
positive confirmation tone
correct input or correct action
negative confirmation tone
wrong input or wrong action
8.4. Programming with infrared remote control
8.4.1. Programmering starten
Power supply and control unit
Deactivate and activate programming
mode
Switch programming mode of the
installation on
RUN
PROG
Press the RUN/PROG key briefly. The LED is flashing and you
have 5 minutes to program.