JAA79051-R.3624.A
- L39 ・ AF-S DX18-70/3.5-4.5G -
INSPECTION OF LENS SERVO TIME.
SERVO AMOUNT.
STANDARD.
1.
[ Df1 ]
93ms OR LESS.
2.
[ Df2 ]
120ms OR LESS.
3.
[ Df3 ]
146ms OR LESS.
4.
[ Df4 ]
186ms OR LESS.
5.
[ Df5 ]
219ms OR LESS.
6.
[ Df6 ]
253ms OR LESS.
7.DRIVING TO INFINITY.
8.DRIVING TO CLOSE.
9.RETURNING TO FOCAL DISTANCE SET-UP MENU.
(4)
Screen of "INSPECTION OF LENS SERVO TIME"
Connect the probes of oscilloscope to E and H terminals of the AF-I communication box (J15306-1). Select each
servo driving amount. The lens servo drive time should be within the standard respectively.
Note
:
If the MF ring is rotated during inspection, the waveform becomes abnormal value. Therefore, do NOT touch the
MF ring during inspection. Make the inspection by maintaining the below 5 positions.
Lens inclination
Position of index window
Horizontal
Up, right and left
Front lens group 90° upward
Front lens group 90° downward
(Lens positions at inspection)
●Setting of oscilloscope
V/Div
:5V
Coupling
:DC
Time/Div
:20
m Sec
Trigger Mode
:SGL(S)
Trigger Coupling
:DC
Trigger Source
:CH1
※
The waveforms of E and H terminals include a
start of going up and a start of going down.
down for
E terminal
H terminal
E terminal
H terminal
Servo driving time
Servo driving time
INC